TRIPLE EOL Jumpers
TRIPLE
EOL Jumpers
TAMPER EOL (J4) ALARM EOL (J5)
J4
TAMPER EOL
JUMPERS
6.8K
5.6K
4.7K
2.2K
1K
No Resistor
(Factory Settings)
ALARM
N
J5
ALARM EOL
JUMPERS
No Resistor
(Factory Settings)
All manuals and user guides at all-guides.com
Jumpers J4 and J5 allow the selection of Tamper
TAMPER EOL
and Alarm resistance (1K, 2.2K, 4.7K, 5.6K, 6.8K)
according to the control panel (see Figure 6
J4
below). Jumper J6 allows the selection of 12K for
Fault/Anti-Mask.
Follow the terminal block connection diagram in
J5
ALARM EOL
Figure 6 when connecting the detector to a
FAULT/AM EOL
Double/Triple End Of Line (DEOL/TEOL) Zone.
12K
SHORT
AM/FAULT
Short AM/FAULT (J25)
J5
ALARM EOL
JUMPERS
6.8K
5.6K
4.7K
2.2K
1K
No Resistor
(Factory Settings)
PANEL TEOL
PANEL DEOL
-
FREE
TAMPER
-
+
N.O.
N.C.
COM
(YEL)
C
.
.
J4
TAMPER EOL
JUMPERS
6.8K
6.8K
5.6K
5.6K
4.7K
4.7K
2.2K
2.2K
1K
1K
No Resistor
(Factory Settings)
Figure 6
WatchIN Installation Manual
J25
AM
FAULT
/
Open
Short
LED
SET/
FREE
TEST
AM
ENBL
(GRN)
UNSET
SHORT AM/FAULT
TAMPER
J6
J25
FAULT
AM
FAULT
/
Open
Short
FAULT/AM EOL (J6)
J6
FAULT
AM EOL
/
JUMPERS
12K
Open
Short
FAULT/AM
AM EOL
/
JUMPERS
12K
Open
Short