Material Safety Data Sheet
# 58367401
Print Cartridge P/N 52118901
For more information, contact Oki Data at: 2000 Bishops
Gate Boulevard, Mount Laurel, NJ 08054-4620.
Emergency Information (US and Canada only): call
1-800-654-3282.
Emergency First Aid Procedures _____
Toner inhaled.
Remove person to fresh air. Rinse mouth with water.
Toner swallowed (ingested).
Rinse out mouth with water and give several glasses of
water to drink. Seek medical attention.
Toner gets in the eyes.
Flush eyes with large quantities of cool water for 15
minutes, keeping the eyelids open with fingers. Seek
medical attention.
Toner gets on the skin.
Wash toner off the skin with plenty of cool water and soap.
Note: Small amounts of toner on skin or clothing can
easily be removed with soap and cold water. Hot
water makes toner harder to remove.
Hazardous Ingredients ____________
Polyester (40-50% by weight)
CAS#: Not available
OSHA PEL: Not available.
Iron Oxide (40-50% by weight)
CAS#: 1309-38-2
OSHA PEL: Not available.
Amorphous Silica (1-5% by weight)
CAS#: Not available
OSHA PEL: Not available.
Ethylene/Propylene Copolymer (<5% by weight)
CAS#: Not available
OSHA PEL: Not available.
Titanium Dioxide (<1% by weight)
CAS#: Not available
OSHA PEL: Not available.
Physical Data ___________________
Physical State: Solid
Melting/Freezing Point: Not available
Boiling Point: Not applicable
pH: Not available.
Vapor Pressure: Not applicable
Vapor Density (Air=1): Not applicable
Evaporation Rate (Butyl Acetate=1): Not available
Specific Gravity (H
O=1): Not available
2
Solubility in Water: Negligible
Solubility in Solvents: Not available
Coefficient of Water/Oil Distribution: Not available
Appearance and Odor: Black powder, faint odor
Odor Threshold: Not available
Fire and Explosion Hazard Data ______
Flash Point (O°C): Not applicable.
Flammability: Not flammable under conditions of use.
Flammable Limits
Lower Explosive Limit: Not applicable
Upper Explosive Limit: Not applicable
Auto-ignition Temperature: Not applicable
Explosion Data
Like most organic materials in powder form, the toner can
form explosive mixtures when dispersed in air.
Sensitivity to Mechanical Impact: Not available
Sensitivity to Static Discharge: Not available.
Extinguishing Media: Water spray, foam, dry
chemicals.
Special Fire Fighting Procedures: In case of fire, use
extinguishing media. When mounted in the printer, treat
as an electrical fire.
Hazardous Combustion Products: Not applicable
Toxicological Properties ____________
Routes of Entry: Inhalation, Ingestion, Eyes, Skin
Effects of Acute Exposure (based on toxicity data for
similar materials and ingredients):
Swallowed LD50 (rat): > 5.0 g/kg
Skin LD50 (rabbit): > 5.0 g/kg
Inhaled LC50 (rat): > 5 mg/L/4hr
Effects of Chronic Exposure (based on toxicity data
for similar materials and ingredients): The results
obtained from a sponsored, Chronic Toner Inhalation
Study, demonstrated no lung change in rats for the
lowest (1 mg/m3) exposure level (i.e. the level most
relevant to potential human exposure).
A very slight degree of fibrosis was noted in 25% of the
animals at the middle (4 mg/m3) exposure level, while a
slight degree of fibrosis was noted in all the animals at
the highest (16 mg/m3) exposure level.
These findings are attributed to "lung overloading," a
generic response to excessive amounts of any dust
retained in the lungs for a prolonged period. This study
was conducted using a special test toner to comply with
EPA testing protocol. The test toner was ten times more
respirable than commercially available Oki toner, and
would not be functionally suitable for Oki equipment.
Exposure Limits, ACGIH TLV†:
Total: 10 mg/m
Respirable: 3 mg/m
Irritancy: Not an irritant.†
Sensitization (skin, guinea pig): Not a sensitizer.†