Battery Connection
Connect your Inverter to your batteries using the following procedures:
• Connect DC Wiring: Though your
Inverter is a high-efficiency converter of
electricity, its rated output capacity is
limited by the length and gauge of the
cabling running from the battery to the unit.
Use the shortest length and largest diameter
cabling (maximum 4 AWG or 5 mm) to fit
your Inverter's DC Input terminals. Shorter
and heavier gauge cabling reduces DC
voltage drop and allows for maximum
transfer of current. Your Inverter is capable
of delivering peak wattage at up to 200% of
its rated continuous wattage output for brief
periods of time. Heavier gauge cabling
WARNING!
• Failure to properly ground your Inverter to a vehicle's chassis or earth ground may result in a
lethal electrical shock hazard.
• Never attempt to operate your Inverter by connecting it directly to output from an alternator rather
than a battery or battery bank.
• Observe proper polarity with all DC connections.
Vehicular Applications
Your Inverter's Nominal DC Input Voltage must match the voltage of your battery or batteries—12 Volts in most vehicular applications.
It is possible to connect your Inverter to the main battery within your vehicle's electrical system. In many vehicular contexts, the Inverter
will be connected to one or more dedicated auxiliary (house) batteries which are isolated from the drive system to prevent possible draining
of the main battery.
1
12 Volt Alternator
2
Vehicle Battery Ground
3
12 Volt Main Battery
4
12 Volt Auxiliary (House)
Battery
5
UL or CE Approved Fuses &
Fuse Blocks (mounted within
18 inches [45 cm] of the
battery)
6
Battery Isolator
7
Large Diameter Cabling,
Maximum 4 AWG or 5 mm
to Fit Terminals
8
12-18 AWG (1-2 mm) Ground
Wire to Vehicle Frame or
Earth Ground
should be used when continuously operating
heavy
draw
conditions. Tighten your Inverter and
battery terminals to approximately 3.5
Newton-meters of torque to create an
efficient
connection
excessive heating at this connection.
Insufficient tightening of the terminals could
void your warranty. See Specifications for
Recommended Cable Sizing.
• Connect Ground: Using a 12-18 AWG
(1-2 mm) wire, directly connect the Main
Ground Screw to the vehicle's chassis or
earth ground. See the Feature Identification
1
2
12 Volts
12 Volt Main Battery Connection—two DC terminals
6
1
12 Volts
12 Volt Main and Auxiliary (House) Battery Connection (Isolated Parallel)—two DC terminals
equipment
under
these
and
to
prevent
3
12 Volts
5
4
2
12 Volts
5
3
12 Volts
2
5
section to locate the Main Ground Screw.
All installations must comply with national
and local codes and ordinances.
• Connect Fuse: Tripp Lite recommends
that you connect your Inverter's positive DC
Terminal directly to a
block(s) within 45 cm (18 inches) of the
battery. The fuse's rating must equal or
exceed the Minimum DC Fuse Rating listed
in your Inverter's specifications. See
Specifications for fuse recommendations.
See diagrams below for proper fuse
placement.
7
12 Volt Inverter
7
12 Volt Inverter
fuse(s) and fuse
8
8