Descargar Imprimir esta página

Fulgor Milano F7DP30S1 Instrucciones Para La Instalación página 7

Publicidad

Idiomas disponibles

Idiomas disponibles

TECHNICAL DATA
For cutout dimensions see following section titled:
Preparing location
F7SP30*1
UPPER CAVITY
F7DP30*1
Installation notes
1. Do not slide oven across floor. Damage to floor covering or
floor could result.
2. The oven support surface must be a minimum 3/4" (2cm)
thick plywood platform.
For single ovens, it must support 202 pounds.
For double ovens, it must support 379 pounds. The
platform must be solid, level and flush with the bottom of
the cabinet cut out.
3. Use extreme caution when moving or installing the oven. It
is very heavy.
DO NOT LIFT THE OVEN BY THE DOOR HANDLE, remove
the door for easier handling and installing.
See REMOVING THE DOOR in the maintenance section of
the Use Care Manual.
4. Be very careful when moving or installing the oven to avoid
damage to the oven frame or damage to the cabinets.
5. Be sure to level the oven. An oven that is not level may
provide poor or inconsistent baking results.
6. Be careful when placing oven. DO NOT pinch the conduit
between the oven back.
Ltr. DIMENSION
A
Cutout Width
B
Cutout Depth
C
Cutout Height
Floor Bottom of Cutout
D
E
Minimum Spacing
F
Minimum Spacing
SINGLE OVEN
DOUBLE OVEN
LOWER CAVITY
Installation Instructions
Electrical Ratings and Maximum Connected Load
@ 120/240 Volts 60 Hz
Amperes
kW
15.4
3.70
Amperes
kW
31.2
7.50
WARNING
Before installing or removing, turn power OFF at the service
panel. Lock service panel to prevent power from being
turned ON accidentally.
Securely fasten oven to cabinet using the screws provided.
Failure to do so could result in oven moving or tipping during
use and causing damage to the oven or cabinets or personal
injury.
Know how to disconnect the power to the oven at the circuit
breaker or fuse box in case of an emergency.
CAUTION
Unit is heavy and requires at least two people or proper
equipment to move.
SINGLE
30"
28 7/16"
(72.2 cm) 28 7/16"
24"
(61.0 cm) 24"
27 3/8"
(69.5 cm) 50"
34"
(86.5 cm) N/A
1/2"
min ( 1.3 cm) 1/2"
3/4"
min ( 1.9 cm) 1"
@ 120/208 Volts 60 Hz
Amperes
kW
16.8
3.50
Amperes
kW
30.3
6.30
DOUBLE
30"
( 72.2 cm)
( 61.0 cm)
(127.0 cm)
min (
1.3 cm)
min (
2.5 cm)
EN
3

Publicidad

loading

Este manual también es adecuado para:

700 serieF7dp30b1F7dp30w1