Idiomas disponibles

  • MEXICANO, página 24
6. Ensure that the float switch (3) is not obstructed
in any way.
7. After use, switch off the pump and remove the
mains plug from the mains.
8. Lift the pump back out of the water.
Manual operation
Where manual operation is preferred, the motor can
be activated by raising the float switch (3) by hand
(ON) or lowering it by hand (OFF).
Finish operation
After use allow the pump to run using clean water
for 2 - 3 minutes in order to remove residues and
particles that may have accumulated in the pump
and outlet hose.
5. MAINTENANCE
Before cleaning and maintenance, always
switch off the machine and remove the
mains plug from the mains.
During maintenance or cleaning never rest
the appliance of the on the turbine
(impeller).
There are no user serviceable parts in this appliance.
If the appliance appears to be blocked, switch off
the power at the mains, remove the plug from the
socket and check the appliance for blockages (see
'Blockages').
BLOCKAGES
If you suspect the pump has become blocked,
switch off the power at the mains socket remove
the plug and examine the turbine. The turbine can
be accessed by removing the securing screws in
the base and/or sub base. Alternately try reaching
the suspected blockage through the outlet (7) in the
side of the pump.
Always flush through with clean water after
every use.
STORAGE AND FROST POTECTION
The submersible pump and accessories that are not
completely drained can be destroyed by frost. Com-
pletely drain the submersible pump and accessories
and protect them against frost.
Keep this appliance in well-ventilated dry premises
WWW.VONROC.COM
with temperature not going below +5°C.
When not in use, keep this appliance stored in a safe
place out of reach of children.
TROUBLE SHOOTING GUIDE
Problem
Cause
Pump does not
No mains supply
start
Floater restricted
Pump is active
Turbine clogged
but no water is
being delivered
Pump will not
Floater restricted Bring floater to a
switch off
Pump will not
Thermal overload
start or stops
safety switch has
during use.
activated
Pump switched
off after short
operating periods
Power has tripped
Turbine clogged
Water too hot
ENVIRONMENT
Faulty and/or discarded electrical or
electronic apparatus have to be collected at
the appropriate recycling locations.
Only for EC countries
Do not dispose of power tools into domestic waste.
According to the European Guideline 2012/19/
EU for Waste Electrical and Electronic Equipment
EN
Remedy
Check mains supply
Bring floater to
higher position
Disconnect pump
from the power
supply and clean or
unblock the turbine
(see 'BLOCKAGES')
lower position
Disconnect from
the power supply,
leave for 2 minutes
and clear the turbi-
ne (if required - see
'Blockages')
Check fuses and
electrical connec-
tions
Disconnect pump
from the power
supply and clean or
unblock the turbine
(see 'BLOCKAGES')
Ensure that the wa-
ter temperature has
not exceeded the
maximum of 35 C