Battery
Plug-In
Service the Solenoid
NOTE: Disassemble the faucet following the steps in the
"Disassemble the Faucet" section.
Disconnect the wire connector and set the faucet body aside.
Remove the two mounting screws using a Phillips screwdriver.
Remove the solenoid unit.
Position the new solenoid unit. Make sure the O-rings are
properly positioned on the bottom of the solenoid.
Tighten the two mounting screws using a Phillips screwdriver.
Proceed to the "Reassemble the Faucet" section.