8 Maintenance
Highly-concentrated water treatment products can damage the pump!
7. Replace the lid, see pump data sheet and tighten by hand.
8.3
Removing salt crystals for pumps with plastic
lanterns (AK version)
1. Disconnect system from the power supply.
2. Carefully remove the salt crystals on the lantern (1) between the fins
3. Remove falling salt crust from the motor base (2).
4. Ensure that the motor shaft is completely free of salt crystals and is
5. Turn the motor shaft on the fan side using a screwdriver. The motor
6. Reconnect to the power supply.
50 EN
VG 766.2000.055
Do not place water treatment products, particularly in tablet form, for
example chlorine tablets, into the strainer basket.
To make it easier to open the lid the next time, tighten the lid by
hand only.
from above using a screwdriver.
visible.
shaft must be easy to turn.