Descargar Imprimir esta página

Beha-Amprobe IRC-110-EUR Manual Del Usuario página 14

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 68
MENU
By default, the product will automatically power off after 1 minute. To
choose when the product will power off after a period of inactivity, change
the settings in the menu.
Available options for the Auto Power Off setting:
• OFF (the camera will not turn off automatically)
• 1 m (1 minute)
• 2 m (2 minutes)
• 5 m (5 minutes)
• 10 m (10 minutes)
SPECIFICATIONS
Temperature measurement
Temperature range
IR accuracy (calibration
geometry with ambient
temperature 23°C ± 2°C)
Display resolution
IR Repeatability
Temperature Coefficient
Distance to spot
Minimum spot size
Response time (95 %)
Spectral response
Emissivity
Visual image with infrared
heat map overlay
ENTER
DOWN
Figure 2.6
Yes, center point
14 °F to 932 °F (-10 °C to 500 °C)
≥ 32 °F (≥ 0 °C): ± 4 °F (± 2 °C) or ± 2 % of the
reading, whichever is greater
< 32 °F (< 0 °C): ± 6 °F (± 3 °C)
0.2 °F / 0.1 °C
± 8 % of the reading or ± 2 °F (± 1 °C), whichever
is greater
0.1 °C/°C or ± 0.1 %/°C of the reading,
whichever is greater
20:1
8 mm
< 125 ms
8 μm to 14 μm
Digitally adjustable from 0.10 to 1.00 by 0.01
Five blending modes (0%, 25%, 50%, 75%
and 100%)
10
BACK TO
MEASUREMENT
UP

Publicidad

loading