Descargar Imprimir esta página
Panamax MAX M5300-EX Manual Del Propietário
Panamax MAX M5300-EX Manual Del Propietário

Panamax MAX M5300-EX Manual Del Propietário

Filtro de ruido emi/rfi nivel 4 con aislamiento entre los bancos de tomacorrientes

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

MAX
5300-EX Owner's Guide
®
LEVEL 4 EMI/RFI Noise Filtration with Isolation Between Outlet Banks:
Your audio/video components are constantly
being bombarded by electromagnetic interfer-
ence (EMI) and radio frequency interference
(RFI) through their power cords. This contam-
inated power can affect audio/video equipment
Model: M5300-EX
Key Features
Sequential Startup/Shutdown:
Complex audio/video systems may be suscep-
tible to voltage transients generated internally
at start-up/shutdown if all of the equipment is
powered on or off at the same time. This can
cause speaker "thumps" which are not only
annoying but can also damage the speakers.
The MAX® 5300-EX is designed to eliminate
these transients by providing a "start-up" delay
for the High-Current outlets and a "shutdown"
delay for the Switched Outlet Bank. This allows
the components plugged into the Switched
Outlet Bank to power-up and stabilize before
any amplifiers and powered sub-woofers are
turned on. This sequence is reversed during
shutdown. The amplifiers and powered sub-
woofers turn off, their power supplies drain,
and then the equipment plugged into the
Switched Outlet Bank is turned off.
Voltage Sense Trigger:
This feature provides an ON/OFF trigger for the
MAX® 5300-EX using a Direct Current voltage
signal. Many components such as pre-ampli-
fiers and receivers have a DC trigger built in,
and will transmit a constant power signal when
turned on and in use. The presence of this
power signal will turn on the MAX® 5300-EX's
switched outlets. When the source component
is turned off, the voltage trigger signal is also
turned off and the MAX ® 5300-EX's shutdown
sequence is initiated. An AC Adapter of the
appropriate voltage, plugged into a switched
outlet, may also be used if a DC trigger is not
built in.
All manuals and user guides at all-guides.com
and will degrade the overall performance of
your entire system. Common symptoms of
contaminated power include pops, hisses,
hums and visual artifacts.
The MAX® 5300-EX voltage sense trigger input
uses a standard 3.5mm (1/8") mini-plug jack.
This jack has an electrically isolated switch built
in. If nothing is inserted into the input jack, the
voltage sense is bypassed and the Power
Button on the front panel has sole control of the
startup/shutdown sequence. If a plug is insert-
ed into the input jack, the front panel switch is
bypassed and the voltage sense becomes the
startup/shutdown trigger. IMPORTANT, Please
Note: The unit needs to be plugged in, and in
the powered OFF state before inserting the DC
input trigger mini-plug.
Automatic Over & Under Voltage Protection:
Panamax's patent pending power monitoring
circuitry constantly monitors the AC line volt-
age for unsafe voltage conditions such as pro-
longed over-voltages and under-voltages
(brownouts). These unsafe conditions pose a
very dangerous threat to all electronic equip-
ment within the home. If the MAX® 5300-EX
senses an unsafe power condition, it will auto-
matically disconnect your equipment from the
power to protect equipment from damage.
Once the voltage returns to a safe level, the
MAX® 5300-EX will automatically reconnect
the power.
Protect or Disconnect AC Surge Protection:
When the MAX® 5300-EX is subjected to a
high voltage surge, its voltage output is limited
to a safe level and the high levels of surge cur-
rent are diverted away from the connected
equipment.
The MAX 5300-EX is designed to filter this
noise, supply clean power to your system and
provide noise isolation between the outlet so
• When subjected to a 6,000V (open circuit
voltage) / 500A (short circuit current) surge,
the MAX® 5300-EX limits its voltage output to
less than 330V peak, UL's best rating. The
MAX® 5300-EX will withstand, without dam-
age, 20,000A surges, far exceeding the UL
requirement of only 3000 Ampere surges.
• If the magnitude of the surge is greater than
the capacity of the surge protection compo-
nents, the MAX® 5300-EX's Protect or
Disconnect' Circuitry will disconnect your
equipment in order to protect it. The MAX®
5300-EX will need to be repaired or replaced by
Panamax if this occurs.
Application Specific Coaxial Signal Line
Protection:
Panamax's exclusive SignalPerfect™ Technolo-
gy provides application specific protection for
your satellite and cable TV equipment. Two
lines of protection are provided for each type.
The satellite connection is for a coaxial cable
connected to a DBS (single or dual LNB) satel-
lite dish. The antenna connection is for a non-
amplified off-air antenna or cable TV line.
The protection circuitry has been optimized for
each application and is not interchangeable.
The jacks are not labeled In and Out. The cir-
cuitry is bidirectional in both signal transmis-
sion and protection capabilities, making it com-
patible with the latest digital cable and satellite
technologies.
that any noise created by an A/V component
can not contaminate the power going to equip-
ment plugged into the other outlet banks.
Cable TV (Including HDTV) – TV tuners oper-
ate at approximately 10 millivolts (0.01 V) and
utilize the frequency spectrum up to 950 MHz.
The clamping level of the MAX® 5300-EX's
cable TV protection circuitry is 1400 millivolts
(1.4 volts). That's less than 1 volt above nor-
mal operating levels.
The circuitry is also
shielded to prevent interference.
Satellite TV - Satellite dish LNB's can require
up to 24 volts to operate and utilize the fre-
quency range of 950 MHz to 2.2 GHz. The
clamping level of the MAX® 5300-EX's satellite
protection circuitry is 25 volts - just 1 volt
above the maximum operating voltage. The
circuitry is also shielded to prevent interfer-
ence.
Telephone Line Protection:
Digital video recorders and satellite TV
receivers require a telephone line connection
for TV show scheduling and/or Pay-Per-View
services. The MAX® 5300-EX also provides
surge protection for this line. One pair of RJ-
11 telephone jacks is provided for this. The cir-
cuitry utilizes auto-resetting PTCRs and solid-
state SIDACtors" for reliability and unsur-
passed protection. The clamping level of the
MAX 5300-EX's telephone protector is 260
volts. This will allow typical ring voltage (90-
130VAC) and operating battery voltage (-48DC)
to pass through the circuit and still protect the
modem in your satellite receiver from damage.
INS0786E Rev A 5/05

Publicidad

loading

Resumen de contenidos para Panamax MAX M5300-EX

  • Página 1 Panamax if this occurs. above the maximum operating voltage. The shutdown. The amplifiers and powered sub- Panamax’s patent pending power monitoring circuitry is also shielded to prevent interfer- woofers turn off, their power supplies drain, circuitry constantly monitors the AC line volt- Application Specific Coaxial Signal Line ence.
  • Página 2 All manuals and user guides at all-guides.com M5300 -EX Front Panel Features Convenience Power Button Power LEDs Outlet Wiring OK LED Press and hold for 2 sec- Meter Dimmer onds to turn Bank 2 and Indicates the status of the rear panel Provides a quick con- Normally On.
  • Página 3 Power Cord Product warranty (see back panel) © 2005 Panamax. Panamax, MAX and the Panamax logo are registered US trademarks of Panamax. Protect or Disconnect and SignalPerfect are trademarks of Panamax. SIDACtor is a registered US trademark of Teccor Electronics, Inc.
  • Página 4 Panamax Power Conditioner Limited Connected Equipment Protection Warranty Valid only in the United States and Canada. It is the policy of Panamax that it will, at its 3. NOTIFICATION: You must notify Panamax Panamax reserves the right to inspect the dam- or controversy between you and Panamax.
  • Página 5 MAX® 5300-EX es de 25 voltios – solo cador y subwoofer sean encendidos. Al apagar Protección automática de sobretensión y Panamax si esto ocurre. 1 voltio sobre el voltaje máximo de operación. la secuencia es en reversa. Los amplificadores subtensión:...
  • Página 6 All manuals and user guides at all-guides.com M5300-EX Botón de Energía Tomacorriente de Reductor de Presionar y sostener por 2 Conveniencia LED Alambrado OK Intensidad LEDs de Energía segundos para encender o Le proporciona una Normalmente encendi- Control del brillo del Indica el estado de los tomacorri- apagar los tomacorrientes forma conveniente y...
  • Página 7 Garantía de mercancía © 2005 Panamax. Panamax, MAX y el logo de Panamax son marcas registradas de Panamax en los Estados Unidos. Protect or Disconnect y SignalPerfect son marcas registradas de Panamax. SIDACtor es una marca registrada de Teccor Electronics, Inc.
  • Página 8 Agentes de Internet Protección de Equipo Conectado al menos que Garantía de Protección de Equipo Conectado a un Acondicionador de energía de Panamax Sólo es válido en los Estados Unidos y Canadá Es la garantía de Panamax, a su discreción absolu- NOTIFICACION: Usted deberá...
  • Página 9 950 MHz à 2.2 GHz. Le seuil de calage woofers excités soient mis sous tension. Le sions et les sous-tensions : faudrait confier le MAX® 5300-EX à Panamax à du circuit de protection pour la télévision par processus est inversé lors de l’arrêt. Les Le circuit de contrôle de puissance en attente...
  • Página 10 All manuals and user guides at all-guides.com M5300-EX Interrupteur Appuyez sur le bouton et Atténuateur de maintenez-le enfoncé pen- Prise utilitaire luminosité dant deux secondes pour Voyant de bon état Voyants DEL de puissance Elle procure un bouton-pression mettre en marche ou étein- du câblage Indica el estado de los tomacorri- moyen facile de...
  • Página 11 Feuillet de garantie du produit Panamax, MAX et le logotype Panamax sont des marques de commerce enregistrées aux États-Unis de Panamax. Protect or Disconnect et SignalPerfect sont des marques de commerce de Panamax. SIDACtor est une marque de commerce enregistrée aux États-Unis de Teccor Electronics, Inc.
  • Página 12 GARANTIE DE PROTECTION LIMITÉE DE L’ÉQUIPEMENT BRANCHÉ SUR LE CONDITIONNEUR D’ALIMENTATION PANAMAX Valide uniquement au Canada et aux États-Unis La politique de Panamax consiste, au choix de celle- 3.