Quick Installation
Optional Installation
The UPS includes a USB communication port, a
serial port and tel/DSL/Ethernet surge protection
jacks (not compatible with PoE applications). These
connections are optional, as the UPS will work
properly without them.
Basic Operation
UPS ON/OFF
• Plug the UPS into a live, grounded outlet: The entire LCD screen will illuminate for
5 seconds, then the display will report output voltage of "0V". The BATTERY / SURGE
PROTECTED outlets will be OFF and the SURGE ONLY outlets will be ON. The battery charger
will engage as necessary.
• Plug equipment into the UPS: You will overload the UPS if the total volt-amp (VA) ratings
for all the equipment connected to the BATTERY/SURGE PROTECTED outlets exceed the
UPS output capacity. To find your equipment's VA ratings, look on their nameplates. If the
equipment is listed in amps (A), multiply the number of amps by 120 to determine VA. For
example: 1A × 120 = 120VA.
• Turn the UPS on: Press and hold the power button until the alarm begins to sound, then
release. The UPS alarm will beep once briefly. The BATTERY/SURGE PROTECTED outlets
will begin passing AC line power. The UPS will automatically recharge internal batteries
as needed. Once turned on, your UPS is ready to protect connected equipment from
blackouts, brownouts, overvoltages and transient surges.
• Turn the UPS off: Press the power button.
Note: UPS system will function properly upon initial startup; however, maximum runtime for the
unit's battery will only be accessible after it has been charged for 24 hours.