Enclosure Configuration
Combining (Baying) Enclosures
WARNING: Combining enclosures is not a substitute for stabilizing the enclosures. Each enclosure in a bay of combined enclosures requires the same stabilizing
measures as a standalone enclosure.
1
Arrange the enclosures in the correct position for baying.
2
Each enclosure includes 4 baying brackets
adjoining enclosure. The baying connection points already contain screws. Remove the screw from each
baying connection point in the adjoining enclosure.
3
Loosen the screw in each baying bracket and turn each bracket 90 degrees toward the adjoining enclosure,
aligning each bracket with the corresponding baying connection point on the adjoining enclosure.
4
Connect each bracket to the adjoining enclosure using the screws you removed in step 2, but do not
tighten the screws completely. Adjust the position of the enclosures as needed. If you want the centers of
the enclosures to be 24 inches (61 cm) apart/29.9 inches (76 cm) for the SR42UBWD, use the outside hole
C
of the bracket
. If you want the centers to be 60 cm (23.6 inches) apart/75 cm (29.5 inches) for the
SR42UBWD, use the middle hole of the bracket
enclosures do not need further adjustment, tighten all screws.
Note: You may wish to remove the doors from the enclosures before combining them. Reinstalling the doors
afterward is optional. Remove the interior side panels before baying enclosures if you wish to enable access
between enclosures.
Equipment Installation
WARNING: Do not install equipment until you have stabilized the enclosure. Install heavier equipment first and install it toward the bottom of the enclosure.
Install equipment starting from the bottom of the enclosure and proceeding toward the top of the enclosure - never the reverse. If using sliding equipment rails,
be careful when extending the rails. Do not extend more than one set of sliding equipment rails at one time. Avoid extending sliding equipment rails near the top
of the enclosure.
Note: The square holes at the middle of each rack unit are numbered and also include a small notch to aid identification. A single rack unit includes the space occupied
by the numbered hole and the holes directly above and below.
201112001_L 93-2723.indd 11
All manuals and user guides at all-guides.com
A
that correspond to baying connection points