Changing
To
Another
3MrM Adhesive Requiring
A
Different Temperature Module
I
Caution
Use
only the proper temperature
module for the 3M QuadrackrM-
shaped
adhesive
used.
Failure
to do
so
may
cause
burns
or
damage applicator. Refer to
Table
1
for
proper
module
selection
for 3M
Quadrack-
shaped adhesives.
7\
Caution
Allow
applicator to cool to room
temperature
before servicing.
Failure to do
so
may
cause
burns.
1.
Make
sure
the proper temperature module
is in the applicator for
the
adhesive then
in the entry track.
See
Table
1
on
page
4 which lists
3M
adhesives
and
their corresponding temperature modules.
2.
Extrude the remaining adhesive from the entry track.
3.
Turn the applicator
offby
pressing the
rocker switch
at
the rear
of
the handle
(see
Figure K). The red visor on the rocker switch
disappears,
indicating the applicator is off.
4.
Unplug the applicator and allow
it
to cool to room temperature.
On/Otf Switch
Figure
K
5.
Remove the temperature module
by
simultaneously
unscrewing the
fastener
and
lifting
the
module out
(see
figure
L).
Save
the
module
for
possible
reuse.
Note:
Do not unscrew the fastener more than 8 turns before
lifting
the
module out.
Temperature
Module
\
O
10
Figure
L
o
3M