Operating mode
1 6 12 18 24
C1
15:26:38
MENU
1
Res.
Technical Data
Dimensions H x W x D 45 x 35 x 60 mm
Weight g (approx.)
170
Supply voltage
see imprint on device
Power consumption
5 VA
Switching capacity
- ohmic load
(VDE, IEC)
16 A/250 VAC
- inductive load
cos ϕ 0.6
8 A/250 VAC
- Incandescent
lamp load
1,000 W
Switching output
potential-free
Switch contacts
1 or 2 changeover
contact(s)
GB
Info
Left-hand button = Channel 1
Right-hand button = Channel 2 (only with
Press 1 x = FIX ON = continuous ON
Press 2 x = FIX OFF = continuous OFF
Press 3 x = return to Auto mode
FIX ON:
FIX
FIX OFF:
FIX
(no display) programmed switching times
AUTO:
Ambient temperature -13°F to 131°F (25°C
Protection class
Accuracy
Reserve power
Shortest switching time 1 min.
Memory spaces
Block formation of
day of the week
Switching status
display
Sealable
27
27
2-channel version)
to +55°C)
II
typ. ±2.5 s/day
at 68°F (20°C)
3 years from factory
at +20°C (20°C)
50
fixed/free selection
yes
yes