Descargar Imprimir esta página

Cardin Elettronica SLX324 Instrucciones Para La Instalación página 20

Automatización para cancillas correderas con motor de corriente continua

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 38
PROGRAMMING PROCEDURE
(gate travel distance and current sensor)
• The installation of anti-derailment buffers is absolutely obligatory.
• Make sure the safety devices are at rest and the ECU is receiving mains power
otherwise you will not be able to enter programming.
• It is not possible to enter programming when working off battery power.
• Before programming set the main operating parameters in the "OPTIONS"
menu.
Press and hold down prog/ok for 4 seconds
PROGRAM
TB FI
TA TD
FS CP
TC TAL
00.000.007
07-06-13 15.35
"PROG/OK" for 4 sec.
PAUSE
TB FI
TA TD
FS CP
TC TAL
AUTO PROG.
00.000.007
07-06-13 15.35
"PROG/OK"
PAUSA
[030]
TB FI
TA TD
The pause time count will start (min. 2 seconds: max. 240
FS CP
TC TAL
seconds) indicated by "PAUSE" and the elapsed time
AUTO PROG.
appearing on the display
00.000.007
07-06-13 15.35
"PROG/OK"
OPENING
TB FI
TA TD
Press "PROG" to set the pause time to the required value. The
FS CP
TC TAL
gate will now open slowly in order to nd the completely open
AUTO PROG.
position.
00.000.007
07-06-13 15.35
When the gate reaches the completely open travel limit it will invert
the travel direction and after moving a few centimetres it will open
again to con rm the completely open position. At this point the gate
AUTOMATIC
will start to close. When the gate reaches the completely closed
PROGRAMMING CYCLE
travel limit it will invert the travel direction and after moving a few
centimetres it will close again to con rm the completely closed
position.
CLOSING
TB FI
TA TD
After carrying out this manouvre the control logic will carry out a
FS CP
TC TAL
complete opening and closing cycle at the standard operating
AUTO PROG.
00.000.007
speed in order to calibrate the current sensor.
07-06-13 15.35
PROGRAM
TB FI
TA TD
When the gate reaches the completely closed position the
FS CP
TC TAL
programmer saves the parameters and quits the
programming mode.
00.000.007
You will have to repeat the programming procedure.
07-06-13 15.35
REPOSITIONING
Attention! During the repositioning manoeuvre the current sensor value
could be altered. At the end of the manoeuvre, however, it will reset
automatically to the chosen value.
If the programmer blocks due to an encoder count error ("Error ENC" on the dis-
play), after a programmer reset ("Out of pos."), when the motor has been released
("Released motor") or there is a problem with the motor ("Mot error") the warning
lights and indicator light will flash simultaneously for 2 seconds and will then switch
off for 10 seconds.
If in this stage you send a (TA, TC, TAL or TD) command to the programmer.
The programmer will move the gates slowly to the completely closed position (2 times
as in the programming procedure) in order to recover the correct position.
At this point the programmer will function normally. If a "TA" command is given the
positioning recovery is carried out in the opening direction.
No commands will be accepted during repositioning but the security devices will cut
in and block all movement if they go into alarm.
To interrupt the repositioning manoeuvre press the "PROG" or "TB" button.
REMOTE CONTROL
The system can be remotely activated using radio control devices; each channel
has a choice of 7 possible functions: open - shut - limited opening - sequential
command - CH2 output - stop - events on/off.
To set the functions to channels "A","B","C","D" use the command "CHANNEL
FUNCTIONS" from the "REMOTE" menu. The sequential command may be set to
"open-stop-shut-stop" or "open-close".
1...4... sec.
The operation has not succeeded.
Memory module (MM)
This is extractable, furnished with a non volatile EEPROM type memory and contains
the transmitter codes and allows you to memorise up to 300 codes. The programmed
codes are maintained in this module even during blackouts.
Before memorising the transmitters for the first time remember to cancel the entire
memory content.
If the electronic card has to be replaced due to failure, the module can be extracted
from it and inserted into the new card. Make sure that the module is correctly
inserted as shown in fig. 2.
TRANSMITTER CODE MANAGEMENT
Memorising a channel
1. Scroll to the "MEMORISATION" step in the "REMOTE" menu and confirm using
the "PROG/OK" button:
the indication "Activation 1" will flash on the LCD.
2. Activate the transmitter channel that is to be memorised:
the indication "Activation 2" will flash on the LCD.
3. Activate the transmitter again (same transmitter, same channel
the indication "Code memorised" will flash on the LCD.
The number of channels already present in the memory is shown on the first line
in brackets.
*
if the channel is different or it is a different transmitter (point three) the memorisation
attempt will abort without success however "Activation 1" will still flash on the LCD.
Note: It is not possible to memorise a code which is already in memory: if you attempt
this the indication "COD. IN MEM." (point one) will appear on the LCD.
Cancelling a channel:
1. Scroll to the "CANCELLATION" step in the "REMOTE" menu and confirm using
the "PROG/OK" button:
the indication "Activation 1" will flash on the LCD.
2. Activate the transmitter channel that is to be cancelled:
the indication "Activation 2" will flash on the LCD.
3. Activate the transmitter again (same transmitter, same channel
the indication "Code cancelled" will flash on the LCD.
The number of channels already present in the memory is shown on the first line
in brackets.
*
if the channel is different or it is a different transmitter (point three) the cancellation
attempt will abort without success however "Activation 1" will still flash on the LCD.
Note: It is not possible to cancel a code which is not already in memory: if you
attempt this the indication "COD. NOT MEM." (point one) will appear on the LCD.
Cancelling all user codes from memory:
1. Scroll to the "CANCEL ALL MEMORY" step in the "REMOTE" menu and con-
firm using the "PROG/OK" button: a procedure confirmation request "CANC
ALL MEMORY?" will appear on the LCD (press one of the arrows to exit the
procedure).
2. Press the "PROG/OK" button to confirm the total cancellation:
the indication "CANCELLING" along with a progress bar will appear on the
display.
3. Once the total cancellation has been carried out the display will return to "CANCEL
ALL MEMORY".
Memorising ulterior channels via radio
• The system can be remotely activated using radio control devices; (without opening
the receiver) by setting "MEMO RADIO" has been activated in the "OPTIONS"
menu.
1. Using a transmitter, in which at least one channel
button "A, B, C or D" has already been memorised
in the receiver, press the button in the transmitter
as shown in figure.
Note: all the receivers within range when the channel
button is pressed (and which have at least one of the
transmitter channel buttons memorised) will activate their signal buzzer "B1" (fig. 2).
2. Press one of the channel buttons on the same transmitter. The receivers which do
not contain that channel code will sound a five-second long "beep" and will then
deactivate. The receivers which contain the channel code will sound a one-second
long "beep" and will enter the "programming via radio" mode.
3. Press the previously chosen channel buttons on the transmitter which you wish to
memorise; the receiver will sound 2 "beeps" of half a second each after which the
receiver will be ready to receive another code.
4. To leave the programming mode wait for 3 seconds without pressing any buttons.
The receiver will sound a five-second long "beep" and will then exit the program-
ming mode.
Note: When the memory is entirely occupied the buzzer will sound 10 rapid "beeps"
and will automatically leave the "programming via radio" mode.
The same signal is given each time you try to enter "programming via radio" when
the memory is full.
Note: the memo radio procedure can only be carried out after programming has
terminated and you have quit the setting/programming menu.
20
*
):
*
):
All rights reserved. Unauthorised copying or use of the information contained in this document is punis
Description :
MEMORIZZAZIONE CODICE TX-RX
Drawing number :
DM0531
Product Code :
RCQ449100
Date :
13-04-2001
Draft :
P.J.Heath
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/40183

Publicidad

loading

Este manual también es adecuado para:

Slx serie100/slx324