Descargar Imprimir esta página

Sime QAA70 Manual De Instrucciones página 31

Publicidad

Idiomas disponibles

Idiomas disponibles

– Heating program
– Time setting
– Current values
– Vacation function
With the heating program it is possible to preset the switching time of the temperatures for
a period of a week. The week program is composed by a block of seven days, (1-7) where each
day uses the same program, or single days (1...7) with seven individual programs of 24 hours
(1=Monday, 7= Sunday). Each 24 hours program offers 3 heating periods, each one defined
by a starting moment and a stopping moment. If no heating is desired, it is necessary to input
the same time for start and stop of heating.
Selection of the relevant heating period. It is possible to choose seven days (1-7) or
4
individual days (1...7) (1= Monday, 7= Sunday).
5
Start of phase 1: heating with prescribed mode
6
End of phase 1: heating with reduced mode
7
Start of phase 2: heating with prescribed mode
8
End of phase 2: heating with reduced mode
9
Start of phase 3: heating with prescribed mode
10
End of phase 3: heating with reduced mode
To set the day of the current week
11
(1= Monday 7= Sunday)
To set current hour and minute
12
With
and
it is possible to set the current time. By pressing both keys the adjust-
ment is accelerated.
13
Display of domestic water temperature
14
Display of current temperature in the boiler
15
Display of zone delivery temperature
To input the number of days of vacation
16
The display will show the vacation symbol on the left of the activation day (
Monday/ 7= Sunday), on the right the number of vacation days.
NOTE:
During vacation time, the regulator is set to availability mode.
When the set period has passed, the regulator switches to automatic mode.
The vacation function can be cancelled by pressing any key of the operating mode.