CODE
POSSIBLE CAUSE
15
Tank pressure exceeds pressure switch cut-in
pressure
16
Extension cord is wrong length or gauge
17
Loose electrical connections
18
Possible defective motor
19
Paint spray on internal motor parts
20
Pressure release valve on pressure switch has not
unloaded head pressure
21
Fuse blown, circuit breaker tripped
22
Worn Belt
23
Restricted air intake filter
POSSIBLE SOLUTION
Motor will start automatically when tank pressure drops below cut-
in pressure of pressure switch.
Check for proper gauge wire and cord length. Refer to the
Extension Cords paragraph in the Installation section.
Contact a D
WALT factory service center or a D
E
service center.
Contact a D
WALT factory service center or a D
E
service center.
Contact a D
WALT factory service center or a D
E
service center. Do not operate the compressor in the paint spray
area. See flammable vapor warning.
Bleed the line by pushing the lever on the pressure switch to the
"OFF" position; if the valve does not open, replace switch.
1. Check fuse box for blown fuse and replace as necessary. Reset
circuit breaker. Do not use a fuse or circuit breaker with higher
rating than that specified for our particular branch circuit.
2. Check for proper fuse. You should use a time delay fuse.
3. Check for low voltage conditions and/or proper extension
cord.
4. Disconnect the other electrical appliances from circuit or oper-
ate the compressor on its own branch circuit.
Contact a D
WALT factory service center or a D
E
service center.
Clean or replace air intake filter. Do not operate the air compressor
with the filter removed. Refer to the Air Filter paragraph in the
Maintenance section.
19
WALT authorized
E
WALT authorized
E
WALT authorized
E
WALT authorized
E