Descargar Imprimir esta página

Schneider Airsystems CPM 342-10-20 W Manual De Instrucciones Original página 8

Ocultar thumbs Ver también para CPM 342-10-20 W:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 46
GB
CPM 342-10-20 W
11
Safety valve
12
Pressure gauge (vessel pressure)
13
Pressure gauge (working pressure)
14
Electric motor
15
External protective motor switch
18
Filter pressure reducer
19
Quick-action coupling (clean, regu-
lated compressed air)
20
Mist oiler
21
Quick-action coupling (oil-mist com-
pressed air)
25
Bracket
26
Lock (bracket)
1.6
Transport
This tool may also be transported horizon-
tally.
1.6.1 Adjusting bracket height
1. Press the locks inward.
2. Withdraw bracket, or push in until it en-
gages.
I/4
1.7
Maintenance
1.7.1 Cleaning the intake filter
1. Unscrew the intake filter. (Fig. 5a)
2. Clean the filter insert using the blow gun,
exchange the filter insert if necessary.
3. Screw the intake filter back on.
1.8
Compressor inspections
Special inspections are not required for this
compressor.
We recommend that a "qualified person"
perform a pressure test on the vessel after
10 years, depending on general levels of
wear and tear.
A "qualified person" should be well informed
about Ordinance on Industrial Safety and
Health (formerly authorised expert)
Contact any of our approved service part-
ners. Most of our service partners have em-
ployees with expert qualifications.
The papers accompanying the vessel are
approval documents and must be kept
throughout the service life of the vessel.
These specifications only apply in Germa-
ny. Equivalent regulations apply in other
countries.

Publicidad

loading

Este manual también es adecuado para:

A 222 011