4. Insert the back glass panel into the clips. Then
tighten the screws on the clips to fix the back
panel in place. Now press gently the top part
of the back panel onto the joint assembly.
5. Fix the top part of the back panel in place with
the supplied joint assembly. Now the sneeze
guard is mounted.
CT393-CT395_ML_A5_v1_171219.indb 5
All manuals and user guides at all-guidesbox.com
Operation
Storing Food
To get the best results from your POLAR appliance,
follow these instructions:
•
Only store foodstuffs in the appliance when it
has reached the correct operating temperature.
•
Do not place uncovered hot food or liquid
inside the appliance.
•
Wrap or cover food where possible.
•
Do not obstruct the fans inside the appliance.
•
Avoid opening the doors for prolonged periods
of time.
Turn On
1. Ensure the power switch is set to [O] and turn
on at the socket.
2. Switch on the Power [I]. The current
temperature within the appliance is displayed.
Control Panel
Set the Operating Temperature
1. Hold the SET button for 3 seconds. The value
of the current set point will be displayed.
2. Press the
required temperature.
3. Press the SET button to store the temperature.
Manual Defrost
•
The appliance will automatically run a defrost
cycle every six hours.
•
To manually defrost the appliance: Press
and hold the defrost button "aux" for 2
seconds to begin a manual defrost. The defrost
light illuminates.
UK
or
buttons to display the
2017/12/19 10:28
5