Descargar Imprimir esta página

EMAK EFCO IP 1150 S Manual De Instrucciones página 21

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 31
IMPORTANT: Only clean or filtered water should
be used for intake. The delivery of the water
intake tap should be equal to the double of the
maximum pump range.
Place the cleaner as close to the water supply
system as possible.
Failure to comply with the above conditions
causes serious mechanical damage to the
pump and the loss of warranty cover.
Water supply from the potable water mains
· Connect a supply hose (not included) to the
water inlet of the unit and to the water supply.
· Open the tap.
Water supply from an open container
· Unscrew the coupling part for the water inlet.
· Screw the suction hose with filter (not included)
onto the water connection of the unit.
· Hang the filter in the container.
· Vent the unit before operation.
· Unscrew the high-pressure line at the high pres-
sure outlet of the unit.
· Switch on the unit and let it run until water free
of bubbles emerges at the high-pressure outlet.
· Switch off the unit and screw on the highpressu-
re hose again.
> ELECTRICITY SUPPLY
- The electrical connection of the appliance must
be carried out by a QUALIFIED
ELECTRICIST and conform to the norm IEC 60364-
1.
WARNING: Before connecting the appliance,
make sure that the nameplate data are the same
as those of the electrical mains and that the so-
cket is protected by a differential security breaker
with tripping sensitivity below
0.03 A - 30 ms.
- If the appliance's plug is not compatible with the
socket, have the socket replaced with another of
suitable type by professionally qualified staff.
- Never use the appliance in ambient temperatu-
res below 0° C if it is equipped with a PVC
(H VV-F) cable.
WARNING: Inadequate extension cords can be
dangerous. If an extension cord is used, it must
be suitable for outdoor use connections must be
dry, away from the ground and a cable reel must
be used so that the socket is at a distance of at
least 60 mm from the ground.
<16 A
<20 m
ø 1,5 mm
14 AWG
20 m - 50 m ø 2,5 mm
12 AWG
IMPORTANT: The Total Stop device, which stops
the machine during the bypass phase. To start
the water cleaner, it is therefore necessary to set
the switch on position (I)"ON"; after that press the
pistol trigger. The Total Stop System will start the
machine and will stop it automatically when the
trigger is released. It is advisable to put on the
safety of the pistol trigger whenever the machine
is stopped, in order to avoid unintentional
starting.
· Any automatic start of the machine
without pressing the gun trigger is
attributable to air bubbles in the water
or other similar phenomena which do not
imply the existence of any defects in the
machine.
· Do not leave the appliance unattended
during the standby for more than 5
minutes. Contrarily, for the safety of the
appliance it is necessary to re-turn the
switch into the (0) OFF position.
· Please check that the coupling of the high
pressure hose with the appliance and the
gun supplied as standard equipment made
correctly, that is to say without any water
leak.
SWITCHING OFF
See fig. C
CARE AND MAINTENANCE
See fig. G
WARNING: machine shall be disconnected from
its power source, by removing the plug from the
socket-outlet, after finishing work and during
cleaning.
WARNING: Do not spray the appliance with
water and do not use detergents or aggressive
solvents. Machine could be damaged.
GB
<25 A
ø 2,5 mm
2
2
12 AWG
ø 4,0 mm
2
2
10 AWG
21

Publicidad

loading

Este manual también es adecuado para:

Oleo-mac pw 115 c