9.
COMMISSIONING
Upon completion of the hydraulic and electrical connections, proceed with commissioning of the control
panel.
Make sure that the water level in the pool is correct and that the sensor is positioned as described in
the previous chapter.
Move the control switch to the «ON» position to turn on the RED 1 control panel.
Unscrew the nut to remove the sensor from the sensor housing bracket and keep it out of the water for
several seconds. The solenoid valve should open. When you plunge the sensor back into the water, the
solenoid valve should close.
10.
OPERATION ANOMALIES
The solenoid valve does not open:
Check that it is supplied with 24 V.
Check that the sensor is placed at the correct level.
Check the electrical connections.
Check the power supply to the transformer.
Check that the sensor has not been installed upside down.
11.
ELECTRIC WIRING
The control panel is fitted with a mechanism that delays start up to prevent it from being tripped unduly by
agitation of the pool water.
The time delay can be set to between 0 and 30 seconds and is pre-set in the factory.