1.6 ELECTRICAL CONNECTION
When the appliance is delivered it is set to work at the voltage given
on the rating plate affixed on the right side of the appliance.
The effectiveness of the equipotential system of which the appliance is
part of, must conform to current standards.
Connect using the screw you find in the back side of the oven, marked
with the word EQUIPOTENTIAL.
The Manufacturer declines all and every responsibility if this important
accident prevention norm is not complied with. If the feeding cable is
damaged, it must be replaced by the technical service or in any case
by similar qualified personnel, in order to avoid any risk.
1.7 TECHNICAL DATA FOR ELECTRICAL CONNECTION
Model
4 x 2/3 GN
4 x 1/1 GN
7 x 2/3 GN
7 x 1/1 GN
11 x 1/1 GN
2.3 WATER FEATURES
The water must be suitable to human use with the following characteristics:
Temperature: included between 15 – 20°C
Total hardness: included between 4 and 12 °f (French degrees), it is advisable to install a softener upstream
from the appliance that will maintain the hardness level at the mentioned values.
Pressure: included between 150 and 250 KPa (1,5 – 2,5 bar).
Attention: higher water pressure values result in increased water consumption and can compromise
the correct functioning of some components.
Maximum chloride concentration (Cl-): less than 150 mg/litre.
Chlorine concentration (Cl2): less than 0.2 mg/litre.
pH: more than 7.
Water conductivity: included between 50 and 2000 µS/cm.
Attention: Water treatment systems that bring to different values to the ones above mentioned au-
tomatically invalidate the guarantee.
The use of dosing systems designed to prevent the build-up of lime-scale in pipes (i.e. polyphosphate dosing
systems) is also prohibited since it may impair the performance of the appliance.
2.4 TECNICAL DATA TABLE FOR THE WATER SYSTEM
Water flow rate regulator for steam
generation in combined and steam
cycle.
Water flow rate regulator drain steam
condenser.
Power loading
no. and motor
and voltage
4.3 kW
380-415 V 3N ~
50/60 Hz
2.7 kW
220-240 V 1N ~
50/60 Hz
5.2 kW
380-415 V 3N ~
50/60 Hz
5.2 kW
380-415 V 3N ~
50/60 Hz
8.8 kW
380-415 V 3N ~
50/60 Hz
15 kW
380-415 V 3N ~
50/60 Hz
4 x 2/3 GN
Ø 0.4 mm
Ø 0.7 mm
Heating
power
power
1 x 250 W
3.9 kW
1 x 250 W
4.9 kW
1 x 250 W
4.9 kW
1 x 250 W
8.5 kW
2 x 250 W
14.4 kW
4 x 1/1 GN
7 x 2/3 GN
Ø 0.4 mm
Ø 0.5 mm
Ø 0.7 mm
Ø 0.7 mm
11
Absorbed
Feed cable
current
section
5 x 1.5 mm
7.5 A
3 x 1.5 mm
8.5 A
5 x 1.5 mm
8.5 A
5 x 1.5 mm
14.5 A
5 x 2.5 mm
25 A
5 x 4.0 mm
7 x 1/1 GN
11 x 1/1 GN
Ø 0.5 mm
Ø 0.5 mm
Ø 0.7 mm
Ø 0.7 mm
EN
2
2
2
2
2
2