TECHNICAL DATA
Contol unit supply
Power supply
Output supply
Maximum motor current
Output supply accessories
Protection level
Operating temp.
Radio receiver
Rolling code transmitters supported 64
IMPORTANT: The control unit is equipped with the Autoset function to automatically set the main functioning values based on the
type of installation.
The AUTOSET function must be repeated at every function parameter change or upon change of automation conditions. See the
AUTO menu for further information.
Wire connections shown in Fig. 1 are described hereunder:
Terminal No.
Function
1-2
Motor 1
3-4
Motor 2
5-6
Flashing light
SCA/
9-10
PHOTO TEST/
2 CH
11-12
24 Vac/dc
13-25
COM/ENC+
14
SWO1/ENC1
15
SWC1
16
SWO2/ENC2
17
SWC2
18
PHOTO/BAR
19
PHOTC
20
STOP
23
PED
24
Step-by-Step
26
ENC-
31-32
Antenna
+ / -
24VAC/dc
24 Vdc
230 Vac 50/60 Hz or 115Vac 50/60Hz according to the version
1/2 motor 24Vdc
2.5+2.5 A
24Vdc 500mA max.
IP54
-20°C / +70°C
built in 433,92 MHz confgurabile (rolling-code or programmable + rolling-code)
HEADY 24 CONTROL UNIT
AUTOSET FUNCTION
WIRE DIAGRAM
Connection, motor 1: 24VDC 2.5A max
Connection, motor 2: 24VDC 2.55A max
Connection, flashing light 24VDC 15W max.
Normally Open, voltage-free contact, configurable as open gate indicator light, photocell
test or second radio channel (see Fig. 4).
For use as "Open gate indicator" the TEST1 and TEST2 logics must be OFF
For use as photocell test it is sufficient to activate one or both TEST logics and connect
the photocells as indicated in Fig.3.
Output, accessory power supply, 24VAC/0.5A max.
IMPORTANT: If the battery charger board is installed, the output (without mains power
connected) has a 24Vdc polarised voltage.
Make sure the devices are correctly connected (i.e. 11:+24Vdc / 12:-0Vdc).
Common for limit switch and all the command inlets or encoder power supply.
Motor 1 OPEN limit switch input (N.C. contact) or Motor 1 Encoder connection.
Motor 1 CLOSE limit switch input, (N.C. Contact)
Motor 2 OPEN limit switch input, (N.C. Contact) or Motor 2 Encoder connection.
Motor 2 CLOSE limit switch input, (N.C. Contact)
Input, photocell activated in both opening and closing phases
As an alternative, the PHOTO input can be used to connect a safety edge (see BAR log-
ics).
Input, photocell activated in closing phase only (Normally closed contact)
Input, STOP push-button (Normally closed contact)
Input, pedestrian push-button (N.O. (Normally Open) contact). It controls the total opening,
motor 1.
Input, step-by-step push button (Normally open contact)
Input for GND Encoder connection (see Fig.2).
Connection to the built-in radio receiver card (31-signal/32-screen).
Input, 24VAC/24VDC power supply.
In case of use of plug batteries connect the battery charging card as indicated in the specific
installation instructions.
Description