Descargar Imprimir esta página

Heath Zenith 9303 Instalación página 2

Luz led de seguridad y detectora de movimiento conectada
Ocultar thumbs Ver también para 9303:

Publicidad

Idiomas disponibles

Idiomas disponibles

IMPORTANT SAFETY AND INSTALLATION INFORMATION
Before installing security light, read all instructions carefully and keep owner's manual for future reference.
• WARNING: To prevent electric shock, ensure that the power is disconnected before installation.
• WARNING: Risk of fire. Keep the lamp heads at least 2 in. from combustible materials.
• WARNING: Shock hazard. For eave mounting, the center of the junction box must be located at least 4 1/2" (11.5 cm)
from the outside edge of the eave.
• CAUTION: To avoid water damage and the risk of electrical shock, the motion sensor controls must be facing the
ground when the installation is complete.
• CAUTION: Keep the lamp heads 30° below horizontal to avoid water damage and electrical shock.
• CAUTION: Burn hazard. Allow the light fixture to cool before touching.
• NOTICE: Do not connect this light fixture to a dimmer switch or timer.
• This light fixture requires 120-volts AC.
• This light fixture must be properly grounded.
• Some electrical codes require installation by a qualified electrician.
• This fixture is designed for outdoor installation and should be mounted to a wall or eaves.
• To achieve best results, this fixture should be mounted 8 feet (2.4 meters) above the ground. Note: If fixture is mounted
higher than 8 ft. (2.4 meters), aiming the sensor down will reduce coverage distance.
The motion sensor on this light fixture detects "motion" by the movement of heat across the coverage area. The motion
sensor is more sensitive to the movement of heat moving across the coverage area and less sensitive to the movement
of heat directly towards it.
Note: Light fixture and sensor should be mounted as shown above when installed (depending upon type of installation).
2
Motion
Least Sensitive
THIS
SIDE
UP
Wall Mount
To see operational and troubleshooting information and videos,
go to www.hzsupport.com
Motion
Sensor
Most Sensitive
Eave Mount
THIS
SIDE
UP
210226-02

Publicidad

loading