If the chimney is cold and cold plugs are created, you may experience smoke leaks during the ignition
phase. In this situation there can be more smoke than usually in the combustion chamber, and some of it
might leak out of the stove. Therefore, if you have a cold chimney that has not been used for a while, we
recommend that you use some wood sticks to heat the chimney and eliminate the cold plug.
5. Maintenance and cleaning of the stove
All maintenance and cleaning of the stove should be carried out when
the stove is cold.
Combustion chamber
The fireproof tiles in the combustion chamber eventually wear out and should be replaced when the cracks
are more than 0.5 cm wide. The durability of the tiles depends on how often and how intensively the stove is
used. You can change the tiles yourself. They are available as a ready-to-use set. You can buy the sets at
www.aduroshop.com.
Glass
Wet wood, unsatisfactory chimney draft, and wrong use of the stove can leave soot stains on the glass
panes. It can easily be removed using a damp cloth that you dip in cold ash and rub on the sooty glass.
Special cleaning agents are also available to remove soot from glass, e.g. the
pad neither scratches nor damages the glass and is for multiple usage. Water or other cleaning agents are
not necessary.
It is common maintenance to tighten the glass fittings and the hinges shortly after the stove has been
installed.
Gaskets
Check if the gaskets around glass and door are properly placed. Over time, the gaskets will wear out and
should therefore be checked regularly. If leakages appear, they should be replaced, as it is essential that the
stove is tight.
Adjusting the door
Adjusting the door and the closing mechanism is a necessary part of the maintenance of the stove, which
you can easily do yourself. If the door hangs on one side, feels sluggish to close or does not close properly,
you should adjust and tighten the hinges and fittings around the door.
Ashes
Empty the ashpan before it gets completely full but always leave a layer of ashes in the combustion chamber
because it insulates and makes it easier to light a fire next time.
Aduro Easy Clean
pad. The