Supplied parts
The following parts make up the LP conversion kit:
NA30*5310F*
The all orifices' positions are marked on the provided sheet. The spud in the
pressure regulator is factory-installed for Natural Gas (NG) use. LP conversion
requires spud removal and reinstallation for LP use.
BURNER ORIFICE SIZES AND OUTPUT RATINGS
(LP Gas [Propane] 10 in WCP)
Burner Location
RF ¹
RF ²
LF ¹
LF ²
RR
LR
Center ²
Model NA30*5310F*
1
2
Model NA36*5310F*
Install_NA30R5310FG_AA_DG68-01133A-00_EN.indd 23
NA36*5310F*
BTU Rate
Orifice size [mm]
12500
1.06
11500
1.04
11500
1.04
8000
0.83
4500
0.62
8000
0.83
12500
1.06
BURNER ORIFICE SIZES AND OUTPUT RATINGS
(Natural Gas 5 in WCP)
Burner Location
BTU Rate
RF ¹
17000
RF ²
13000
LF ¹
13000
LF ²
10000
RR
5000
LR
10000
Center ²
17000
Model NA30*5310F*
1
2
Model NA36*5310F*
NOTE
Orifice markings:
115
115 – Denotes 1.15 mm orifice size opening.
Orifice size [mm]
1.92
1.64
1.64
1.4
1.01
1.4
1.92
English 23
2019-04-12
12:13:38