INSTALL WINDOW PANEL
Installation in a sliding sash window
1
Connect the rain guards to the insect
guard net.
Insert all three projections on each rain
guard into the holes in the insect guard net.
Side "A" will now be at the top, as indicated
in the diagram.
2
Attach the guard combined above to
the window panel.
Push the insect guard net firmly to ensure
that its four projections fit into the holes in
the window panel.
Side "A" will now be at the top, as indicated
in the diagram, when it is installed in the
window.
3
Cut the foam seal A (adhesive type)
to the proper length and attach it to
the window frame.
4
Install the window panel into the win-
dow frame.
Make sure that the exhaust cover is
attached to the window panel.
Inner height of the window:
21.3" (540mm) - 28.3" (718mm)
Use the window panel.
The window panel cannot be installed in
windows less than 21.3" (540mm) high, as
you will be unable to shut the exhaust cover.
(1) Cut the window panel to the same height
as the window.
(2) Open the window sash and place the
window panel on the window frame.
(3) Secure the window panel to the window
frame with 2 screws.