Descargar Imprimir esta página

castorama CAT3 Manual De Instrucciones página 23

Publicidad

RCD Test
Warnings
Observe all safety precautions when
working on live voltages. The RCD
test function can only be used on
protection.
1. Check the instructions on the
specific RCD device you are
testing before proceeding.
2. Press the RCD button on the
RCD receptacle. The RCD
should trip. If not, do not use the
receptacle and consult a qualified
electrician. If it does trip, press
the reset button on the RCD
receptacle.
3. Insert one test probe into hot
side of the outlet being tested.
4. Insert the other test probe into
the ground of the outlet being
tested.
5. The tester should indicate
and wired properly.
6. Press the RCD test button.
7. The indicator lights should
turn off indicating the RCD has
tripped.
18_s1_s15_5059340161952_OPP_A6_IM_Multi-V04.indd 23
EN Use
8. If the RCD does not trip, either
the receptacle is mis-wired or
the RCD is defective. Do not use
the receptacle and consult a
qualified electrician.
NOTE:
The tester cannot test RCD
operation on 2-wire (non-grounded)
outlets.