If you are using a standard DMX controller, you can connect the DMX output of the controller directly to the DMX input of the first unit in a DMX chain.
Always connect the output of one unit with the input of the next unit until all units are connected.
At the last unit, you must close the DMX line with a terminating resistor. Take an XLR connector and solder a 120 Ohm resistor
between signal (-) and signal (+) and connect it to the DMX output of the last unit in the line.
1
Activate
2
Bubble
We recommend a frequent cleaning of the unit. After using the machine, first drain off all the bubble liquid and clean all the water stains before storing.
There are no serviceable parts inside the unit except for the fuse. Repairs and service operations are only to be carried out by authorized
dealers.
Disconnect from mains before starting maintenance operation!
Ensure the fluids do not become contaminated.
•
Ensure the air vents are not clogged by dust. If necessary remove the dust.
•
Ensure that the unit cannot get overheated.
•
•
Wipe up spilled fluid immediately. Moisture and fluid can permanently damage the electrical components of the unit.
•
If you install the unit make 100% sure that a permanent fog-free air supply for the unit is guaranteed. Cooling air with too high fog
concentration (very often in Clubs and Discos) can condensate inside the unit and cause moisture damage.
•
For cleaning the surface of the unit use a suitable, solvent-free cleaner.
It is recommended to run the unit on a monthly basis in order to achieve best performance and output condition.
•
If the fuse is defective, replace the fuse with a fuse of the same type and value. Before replacing the fuse, unplug mains lead.
000-005
No function
001-255
Activation of channel 2
000-025
Off
026-255
On, bubbles production
Procedure:
Step 1: Open the fuse holder on the rear panel with a fitting screwdriver.
Step 2: Remove the old fuse from the fuse holder.
Step 3: Install the new fuse in the fuse holder.
Step 4: Replace the fuse holder in the housing.