1
POWER SWITCH
press to toggle the power on or off.
PROTECT
2
By overheat or when DC is occured at power amp blocks, protection cirquit is activated and „protect" -LED
turns red. The protection cirquit and LED is always activated for 3 seconds after you turn the amplifier on.
LIMIT
3
Lights up orange when the limiter ist working, because the signal level is too high. In this case lower the Gain.
SIGNAL LED
4
Normal indication: The Signal indicator illuminates when the input signal exceeds -35dB, the -15dB indica-
tor illuminates when the signal exceeds -15dB, the -10dB indicator illuminates when the signal exceeds
-10dB, the -5dB indicator illuminates when the when the signal exceeds -5dB.
If no indication: check gain settings and increase gain if necessary. Check input connections and audio
source for signal.
Abnormal indication: if -20dB, -15dB, -10dB, -5dB LED illuminates with no signal
input, there may be system oscillations or some other malfunction. Disconnect the load
and fully reduce the gain. If the LED remains on , the amp may need servicing.