Specification Guidelines - GE PNRQ20RBL Manual Del Propietário

Ocultar thumbs Ver también para PNRQ20RBL:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Specification guidelines.

The system makes a good supply of drinking water each day.
How much it will make depends primarily on these things...
Maximum water hardness @ 6.9 pH recommended to optimize membrane
For water with hardness greater than 10 grains (at 6.9 pH), the use of a
softener is recommended. Failure to install a water softener will reduce the
life of the Reverse Osmosis membrane. See chart for additional information
on the possible need for a water softener.
Maximum turbidity (NTU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<2
Maximum iron, manganese, hydrogen sulfide (ppm) . . . . . . . . . . . . . . . . . . . . .<0.1
Chlorine in water supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.0 ppm Maximum Allowable
Feed water pH limits (pH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4–10
Automatic shutoff control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .yes
Prefilter and postfilter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(FQROPF) Carbon Block
Reverse Osmosis membrane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(FQROMF) Thin Film Polyamide
Storage Tank Dimension (inches) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .height 15" diameter 11"
System Body Dimension (inches) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .height 11" width 10.5" depth 4"
a. If house water pressure is over 80 psi, install a pressure reducing valve in the water supply line. If house water pressure
is under 40 psi, install a Reverse Osmosis booster pump (contact your local plumbing supply company).
Reverse Osmosis membrane.
c. Theoretical tank capacity. When tested according to NSF/ANSI Standard 58 at 50 psig inlet pressure, tank capacity is
2.3 gallons.
4
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
. . . . . . . . . . . . . . . . . . . . . 40–120
. . . . . . . . . . . . . . 40–100
. . . . . . . . . . . . . . . 2000
8
5
7
5
6
Water Softener
not required
10
INCOMING WATER HARDNESS (GPG)
c
a
WATER SOFTENER RECOMMENDED
20
30
40
50
60
b

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pnrq21rbnPnrq21rrb

Tabla de contenido