Relay output (12 V) - Auxiliary heat
This output provides 12 Vdc through a relay. The control logic of the relay output is different for
Aidoo Pro direct expansion AC units and Aidoo Pro air to water units.
Aidoo PRO Direct Expansion - Auxiliary Heat
This output provides 12 Vdc through a relay. It offers control over a heat supply stage in
situations when the unit is unable to reach the setpoint temperature desired by the user.
By default it is disabled.
Aidoo PRO Aerothermal - Production management
The relay activation logic depends on whether the air to water unit is configured to work with
supply water temperature or room temperature. No additional configuration is required in the
Aidoo.
Aerothermal LWT mode
Circuit status
Circuit 1 y Circuit 2 OFF
Circuit 1 and/or Circuit 2 ON
Circuit 1 and/or Circuit 2 on
demand
DHW ON
DHW OFF
Aidoo Pro air to water units can work with up to 2 zones and DHW depending on the
characteristics of each air to water unit. If there is more than one zone, they must all have the
same working settings.
Diagnostic LEDs
Transmission of data to the indoor unit
Reception of data from the indoor unit
Relay
OFF
ON
ON
OFF
OFF
Meaning
Connecting to a Wi-Fi network
Connected to a Wi-Fi network
Connected to the server
Not configured
Cloud Communications
Microprocessor activity
Power supply
Aerothermal TH mode
Circuit status
Circuit 1 y Circuit 2 OFF
Circuit 1 and/or Circuit 2 ON
Circuit 1 and/or Circuit 2 on
demand
DHW ON
DHW OFF
Blinking
Green
Steady
Steady
Blue
Off
Blinking
Blinking
Green
Steady
Blinking
Blinking
Green
Relay
OFF
OFF
ON
OFF
OFF
-
Red
Red
Red
EN
7