In-Place Sanitization; Routine Maintenance - Bras FBM Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

EN GLIS H
F B M U L
5. 3. 4 ASSEMBLY
1
Slide the drip tray into place.
2
Lubricate faucet piston, inside auger and outer spiral (see
points A, B and C of figure 11) only with the grease supplied by
the manufacturer or other food grade approved lubricant.
3
Assemble the faucet by reversing the disassembly steps
(see figure 10)
4
Fit bowl gasket around its seat.
Note: the largest brim of gasket must face against the rear wall
(see figure 12).
5
Insert the auger into the evaporator taking care to
accompany it to the end so as to prevent it from hitting against
the rear wall (see figure 13).
6
Install the outer spiral. Slide it over the evaporator until its
front notch engages with the exposed end of the auger shaft
(see figure 14).
figure 11
figure 12
figure 13
figure 14
7
Push the bowl towards the rear wall of the unit until it fits
snugly around the gasket and its front fastening hooks are
properly engaged (see figure 15).
8
Use fresh product to chase any remaining sanitizer from the
bottom of the bowl(s). Drain this solution. Do not rinse out the
machine.

5. 4 IN-PLACE SANITIZATION

The In-Place Sanitization prior to starting the machine may
be performed, if needed, only as further precaution, in
addition to the Disassembled Parts Sanitization described
before, but never in lieu of it.
1
Prepare two gallons of a warm (45-60°C, 120-140 °F)
sanitizing solution (100 PPM chlorine residual) according to
your local Health Codes and manufacturer's specifications.
2
Pour the solution into the bowl(s).
3
Using a brush suitable for the purpose, wipe the solution on
all surfaces protruding above the solution-level and on the
underside of the top cover(s).
4
Install the top cover(s) and operate the unit. Allow the
solution to agitate for about two minutes. Drain the solution out
of the bowl(s).
5
Use fresh product to chase any remaining sanitizer from the
bottom of the bowl(s). Drain this solution. Do not rinse out the
machine.

6 ROUTINE MAINTENANCE

ATTENTION
In case of damages, the power cord must be replaced by
qualified personnel only in order to prevent any shock
hazard.
1
Daily: inspect the machine for signs of product leaks past
seals and gaskets. If proper assembly does not stop leaks
around seals or gaskets, check for improper lubrication, worn
or damaged parts. Replace parts as needed.
ATTENTION
Before any disassembly and/or cleaning procedure make
sure that the dispenser is disconnected from its power
source by unplugging it or switching off the 2-pole wall
breaker.
8
figure 15

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fbm1pFbm2Fbm3

Tabla de contenido