Schneider Airsystems MAS 575-15-60 D Manual De Instrucciones página 41

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Problem
C
Compressor
not
start
when
switched on.
D
The
compressor
starts
up
briefly
when the switch-on
pressure is reached
or
hums,
switches off auto-
matically.
E
Compressor
continuously.
F
During
operation,
compressed
escapes
via
load-relieving valve.
G
After the switch-off
pressure is reached,
compressed
escapes
via
load-relieving valve
until
switch-on
pressure is reached.
H
Compressor
switches
on
quently.
Cause
does
Vessel pressure is higher than
switch-on pressure.
Power supply faulty.
Protective motor switch inter-
rupts power supply.
Pressure switch defective
Mains connection cable longer
than permitted or the cross
section is too small.
then
runs
Intake filter badly contami-
nated.
Air consumption of compressed
air tools is too high.
Leakage at compressor.
Excessive condensate in the
tank.
Compressed air line leaky
3/2-way valve open/defective
Load-relieving valve leaky.
air
the
Check valve insert leaky or
defective.
air
Check valve is damaged.
the
Excessive condensate in the
fre-
pressure tank.
Compressor overloaded.
Remedy
X
Relieve pressure in the vessel
until the pressure switch is acti-
vated automatically.
X
Have the power supply checked
by a qualified person (service
partner).
X
See item A.
X
Have
the
pressure
changed by a qualified person.
X
Check connection cable length
and
cable
cross-section
Chap. 2.4.4)
X
Clean or replace intake filter.
X
Check the air consumption of the
tools. Contact the service partner
X
Locate leak, contact service part-
ner.
X
Clean
dirt
arrester
Chapter 2.6.14)
X
Clean/replace
3/2-way
(see Chapter2.6.4) or contact
your service partner
X
Check compressed air line, plug
leak.
X
Clean/replace
3/2-way
(see Chapter2.6.4) or contact
your service partner
X
Clean or replace load-relieving
valve.
X
Clean or replace the check valve
insert (see Chap. 2.6.11)
X
Replace check valve.
X
Clean
dirt
arrester
Chapter 2.6.14)
X
See item E
GB
MAS
switch
(see
(see
valve
valve
(see
II/19

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

A 888 009A 888 016A 888 021

Tabla de contenido