Conversion from LP Gas to
Natural Gas
Orifice Change and the Installation of the NG regulator
1.
Before making any connections, check to ensure the
natural gas inlet pressure falls between the allowable
range of 7 in W.C. / 0.25 psi and 14 in W.C. / 0.5 psi. If the
NG inlet pressure does not fall within this range, contact
your local gas supplier.
2.
Turn off the main gas supply valve.
3.
Disconnect 20 lb propane tank (if present).
4.
Turn off burner control valve.
5.
Use screwdriver to remove screw holding the corrugated
pipe connector to the enclosure.
6.
Use adjustable wrench to remove hose and regulator from
corrugated pipe connector.
7.
Remove side burner cooking grid and burner cover.
8.
Remove igniter junction wire from electronic igniter module.
9.
Remove 3 screws off the front baffle.
10. Lift up front baffle away from burner.
11. Use a 6 mm socket and wrench or 6 mm nut driver to
remove the LP gas orifice from the end of gas valve.
13