DIPSWITCH
12
230V
50/60 Hz
Fuse
PRIORITY CONTROL OUT (dipswitch no. 8)
In the OFF position, the priority contact of the
RJ45 PRIORITY OUTPUT connector is disabled.
PRIORITY CONTROL IN (dipswitch no. 7)
In the OFF position, the priority contact of the
Eng
RJ45 PRIORITY INPUT connector is disabled.
PRI-PRO LINK (dipswitches no. 5 y 6)
These two dipswitches link internally the audio
signals H and C (when the input is balanced)
present in the PRIORITY OUTPUT to the
PROGRAM INPUT.They are normally in the OFF
position (separate audio signals). To connect
them, place the corresponding dipswitch in the
ON position.
SHIELD - GND LINK (dipswitches no. 1,2,3 y 4)
These 4 dipswitches allow for the separation of
the cable shield from the internal mass of the unit
for each of the RJ-45 connectors. They are
normally in the ON position (shield and device
mass connected). To separate them, place the
corresponding dipswitch in the OFF position.
PRIORITY CONTROL STRIP
13
Priority is activated by means of these contacts,
facilitating the wiring of
the installation.
The block diagram (see
figure 8) shows a typical
installation example.
1 8
AMPLIFIERS UP-367, UP-247, UP-127 and UP-67
I N P U T / O U T P U T C O N T A C T S
1
2
3
4
5
6
7
8
9
FAIL
6. PRIORITY
24V
8.
24V
FAIL
METAL
SHIELD
SURETY
PAGING
PRI-PRO
O U T P U T S
FAN
LINK
SURETY PAGING
0
4Ω
8Ω
O U T P U T S
16 Ω
50V
70V 100V
POWER
0
4Ω 8Ω 16Ω
50V 70V 100V
SHIELD-GND
SUPPLY
LINK
Zone 1A
UP-127
ON
OFF
PRI-PRO LINK
SHIELD-GND
LINK
Zone 1B
UP-127
ON
OFF
PRI-PRO LINK
SHIELD-GND
LINK
OPTIMUS S.A.
PRIORITY
PRIORITY
U P - 2 4 7
INPUT
OUTPUT
POWER AMPLIFIER
PRI-PRO RJ CONNECTION
240W RMS (312W IHF)
GND
(WHEN BALANCED)
Engineered in EU (Spain)
PRIORITY
CTRL. INPUT
Made in China
ON
OFF
8
GND
SURVEILLANCE
7
6
DIPSWITCH CONFIGURATION
5
ON
OFF
PROGRAM
PROGRAM
3
8. Priority ctrl. out
INPUT
OUTPUT
2
7. Priority ctrl. in
6. Audio C
1
5. Audio H
4. Priority in
3. Priority out
SURVEILLANCE RJ CONNECTION
2. Program in
1. Program out
1. OSC IN
5. OSC OUT 2
6. PRI OUT
2. NC
3. OSC OUT 1
7. +24VDC OUTPUT
4. PROTECT
8.
METAL
GND
SHIELD
Figure 6
PRIORITY
CONTROL INPUT
GND
PRIORITY
INPUT
PRIORITY CTRL.
SW 7
SHLD
AUDIO H
AUDIO C
SW 4
PROGRAM
INPUT
SHLD
AUDIO H
AUDIO C
SW 2
ZONES SELECTOR
MIC
configuration
Zone 2, 3, 4 and 5 UP-127 configuration
configuration
ON
OFF
PRI-PRO LINK
SHIELD-GND
LINK
Version 1.0
To power unit
SW 8
SW 3
SW 5
SW 6
SW 1
OUTPUT - INPUT DIAGRAM
Figure 7
PM-612/0
Priority control
input contact
Priority input
RJ connector
Priority output
C610PAL
RJ connector
Priority control
input contact
Priority input
8 pins RJ45
RJ connector
connectors
Priority output
RJ connector
Priority
Priority control
input contact
Priority input
RJ connector
Priority output
RJ connector
Priority control
input contact
Priority input
RJ connector
Priority output
RJ connector
Priority control
input contact
Priority input
RJ connector
Priority output
RJ connector
Priority control
input contact
Priority input
RJ connector
UP-367, UP-247, UP-127 and UP-67
PRIORITY
OUTPUT
PRIORITY CTRL.
SHLD
AUDIO H
AUDIO C
PROGRAM
OUTPUT
SHLD
AUDIO H
AUDIO C
Figure 8
UP-127
zone 1A
UP-127
zone 1B
UP-127
zone 2
UP-127
zone 3
UP-127
zone 4
UP-127
zone 5