Installation Requirements
Electrical requirements
IMPORTANT
Observe all governing codes and ordinances.
It is the customer's responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is adequate
and in conformance with National Electrical Code,
ANSI/NFPA 70 — latest edition*, or CSA Standards
C22.1-94, Canadian Electrical Code, Part 1 and C22.2
No.0-M91 - latest edition** and all local codes and
ordinances.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that
the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120 volt, 60 Hz., AC only, 15-amp, fused electrical
circuit is required.
If the house has aluminum wiring, follow the
procedure below.
1.
Connect a section of solid copper wire to the pigtail
leads.
2. Connect the aluminum wiring to the added section
of copper wire using special connectors and/or
tools designed and UL listed for joining copper to
aluminum.
Follow the electrical connector manufacturer's
recommended procedure. Aluminum/copper
connection must conform with local codes and
industry accepted wiring practices.
Wire sizes and connections must conform with the
rating of the appliance as specified on the model/
serial rating plate. The model/serial plate is located
behind the filter on the rear wall of the hood.
Wire sizes must conform to the requirements of
the National Electrical Code, ANSI/NFPA 70 (latest
edition), or CSA Standards C22. 1-94, Canadian
Electrical Code, Part 1 and C22.2 No. 0-M91 (latest
edition and all local codes and ordinances).
If provided with an electrical plug, connect the hood to
a receptacle that complies with current regulations and
placed in an accessible position. Where an electrical plug
is not provided (direct connection to electrical network) or
the plug will not be in an accessible position after ins-
tallation, place an approved bipolar switch in accessible
position that provides full disconnection under overvolta-
ge category III conditions, in accordance with local wiring
rules.