Selecting the zone
WARNING!
BUS ADDRESSING CONFLICT
After initialisation, if the zone assigned to the device is already being used by anoth-
er device on the BUS network, an addressing conflict error message will be displayed.
Press the knob to access the configuration page of the BridgeNet Bus network. Proceed
with the correct addressing of the devices according to the instructions in the respective
manuals.
WARNING!
TIME SCHEDULING CONFLICT
A time scheduling conflict error is generated when one of the programmable devices on
the network does not support multi-level programming.
In this case, the programming must be set on "2 levels" through the 0.4.3. parameter.
WARNING!
ROOM TEMPERATURE CORRECTION
In the event of installation on a wall-mounted Remote Modem (Light Gateway), the room
temperature measurement may require a correction.
The technical documentation is available at the following link:
https://www.aristonthermo.com/docs/en/sensyshd/User_
Manual_ExpertControlHD_00.pdf
Diagnostics
https://www.aristonthermo.com/docs/en/sensyshd/SystemInterface_
Parameters_Diagnostics_00.pdf
18 / EN
After, the display screen shows the selection of the zone to be assigned to
the room temperature control device.
Turn the knob to select the desired zone. Press the knob to confirm. By as-
signing zone no. 0 the device will exclusively carry out the function of system
interface. After the zone selection, the system will repeat the initialisation
procedure