One Touch™ Test Mode
To speed up installation and testing, One-Touch™ testing is provided which allows the controller functionality to be
tested at the controller or reader.
Test
Action
Normal Operation
Hold down One-Touch™ button for less
One-Touch™ View
than 2 seconds. Present keys, press
Mode
RTE switches and observe LEDs.
Automatically exits after 2 minutes.
One-Touch™
Hold down One-Touch™ button for 2 to
Active Mode
4 seconds.
Present a key to each reader (the lock
will activate).
Reader and
Press the Request to Exit switch (the
Request to Exit
lock will activate).
Test
Open the door contact.
Present a key to a reader, press the Request to Exit
switch and open the door contact simultaneously.
Auxiliary and Lock
Remove link to 0V on tamper or open circuit tamper
Relays Test
switch.
Remove link to 0V on emergency override or leave
open circuit tamper switch.
Remove the link between TAMP and 0V on the Tamper
& Override terminal block.
Tamper and
Override Test
Remove the link between OVRD and 0V on the Tamper
& Override terminal block.
Hold down One-Touch™ button for less
Leave One-
than 2 seconds. One-Touch™ Test
Touch™ Active
mode will automatically be timed out
Test mode
after 1 hour, power up or power down.
Observation
Controller
System status:
GREEN flashes at
normal rate.
Green
Door status: All
LEDs off.
Green-Red-
Yellow
System status
GREEN flashes at
normal rate.
Green
Door status:
GREEN on, valid
key presented to
Green-Red-
reader.
Yellow
Door status:
GREEN flashes,
invalid key
presented to
Green-Red-
Yellow
reader.
Door status: RED
on, door open.
Green-Red-
Yellow
Door status:
YELLOW on, RTE
switch has been
Green-Red-
pressed.
Yellow
System status:
GREEN flashes
faster than normal.
Green
Door status:
GREEN flashes
once for SIGA,
Green-Red-
twice for SIGB.
Yellow
Door status:
GREEN flashes
three times and
Green-Red-
YELLOW is on.
Yellow
Door status:
GREEN flashes
four times and
Green-Red-
RED is on.
Yellow
The appropriate auxiliary relay is activated.
Both auxiliary relays are activated.
The auxiliary relay is activated.
The auxiliary relay is activated but the door relays are
unaffected.
Both auxiliary and lock relays are activated, the door opens
and the lock operates.
System status:
GREEN flashes at
normal rate again.
Green
– Page 5 of 22 –
Reader
Normal operation of the
reader.
Red
Normal operation of the reader
LED changes, e.g. if default is
red it changes to green.
Green
Reader LED flashes once for
SIGA, twice for SIGB.
Red
Reader LED flashes three
times.
Red
Reader LED flashes four
times.
Red
Reader LED returns to normal