Technical data
Model
Designation
Voltage/frequency
Power rating
Capacity
Max. pump depth
Max. delivery head
Max. water temp.
Max. particle size
Automatic floating
switch
Hose connector
Connection
Water hose coupling
Setup
This submersible pump is intended for use
as a cellar pump to protect against � ooding
and for removal of water in domestic
situations, e.g. in gardens, greenhouses, etc.
There must be suffi cient space around the
pump for the � oat to move freely.
Place the pump in the required location and
then plug it in.
The pump must be on a level surface, so
that there is no risk of it tipping over while
in operation.
The pump can be fully or partially
submerged in water. Tie a piece of rope
around the carrying handle, if necessary,
before submerging in deep water, and also
check that the cord is long enough for the
water depth.
The pump must not be left suspended by its
cord or hose.
Fit a check valve in the pipes, if necessary,
to prevent any back� ow of water when the
pump is stopped.
20
18045
SUBMERSIBLE CLEAN
WATER PUMP
250 W
5.000 l/hour
5 m
6 m
For clean water only!
On: max. 42.5 cm
Off: min. 7.5 cm
With 10 m rubber cable
18044
SUBMERSIBLE DIRTY
WATER PUMP
230-240 V ~ 50 Hz
550 W
10,500 l/hour
7 m
7 m
35 °C
25 mm Ø
On: max. 45 cm
Off: min. 10 cm
3/4'' + 1'' + 1 ¼''
for 1/2" or 3/4" hose
If you are using a collecting vessel, you
should check that it is large enough to
hold the pumped liquid, so that it is not
necessary to interrupt operation of the
pump.
If the pump is being used in a garden pond
containing � sh, you must make sure that
the � sh cannot be sucked into the pump.
Use
The pump can be set to automatically
switch on and off at speci� c water levels.
When adjusting the � oat, it is essential
to do this in a location where it is easily
accessible. The pump can, for example, be
placed in a bowl of water. Position the � oat
in the holder. Lift the � oat to the maximum
position, so the pump begins to run. Lower
the � oat slowly to the minimum position,
until the pump switches off . Remember to
make sure that the pump stops before the
� oat touches the bottom; otherwise the
pump will run dry and could be damaged.
Check that the pump's connections � t
tightly.
18043
550 W
10,500 l/hour
7 m
8 m
25 mm Ø
On: max. 46.5 cm
Off: min. 11.5 cm