TO CONVERT APPLIANCE FOR USE WITH PROPANE GAS
Natural Gas To Propane Gas (LP) Conversion Instructions
WARNING
Propane Gas conversion is to be performed by
a Jenn-Air Authorized Service Contractor (or
other qualified agency) in accordance with the
manufacturer's instructions and all codes and
requirements
of
jurisdiction. Failure to follow instructions could
result in serious injury or property damage. The
qualified agency performing this work assumes
responsibility for this conversion.
BURNER
Left Rear (LR)
Left Front (LF)
Center Rear (CR)
Center Front (CF)
Right Rear (RR)
Right Front (RF)
All manuals and user guides at all-guides.com
the
authority
having
BTU/hr
7500
7500
6500
9000
6500
9000
ELECTRICAL POWER AND GAS MUST BE
TURNED OFF PRIOR TO CONVERSION
Models - JGD8348BDP
Manifold - Propane Gas pressure required - 10² W.C.
Incoming Propane Gas pressure required to appliance
pressure regulator - 11² - 12² W.C.
Propane Conversion Orifice Hoods are supplied with this
model.
Propane Gas input specified - 46,000 BTU/hr.
INCHES
ORIFICE
DIAMETER
#66
.033
#66
.033
#68
.031
#63
.037
#68
.031
#63
.037
8
WARNING
JGD8348BDP
COLOR
Zinc
Zinc
Red
Blue
Red
Blue