Descargar Imprimir esta página

KitchenAid W10289679A Manual De Instrucciones página 15

Publicidad

Idiomas disponibles

Idiomas disponibles

This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.
Substance Reduction
NSF Reduction
Aesthetic Effects
Requirements
Chlorine Taste/Odor
50% reduction
*
Particulate Class I
85% reduction
Contaminant
NSF Reduction
Reduction
Requirements
Lead: @ pH 6.5
0.010 mg/L
Lead: @ pH 8.5
0.010 mg/L
Mercury: @ pH 6.5
0.002 mg/L
Mercury: @ pH 8.5
0.002 mg/L
Benzene
0.005 mg/L
O-Dichlorobenzene
0.6 mg/L
Toxaphene
0.003 mg/L
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.85 gpm (3.2 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Use replacement filter P2RFWG2, part #4396841.
2010 suggested retail price of $39.99 U.S.A./$54.95 Canada.
Prices are subject to change without notice.
Model P2WG2L/P2WG2: Style 1 – When the filter indicator
reads 10%, order a new filter. When the indicator reads 0%, it is
recommended that you replace the filter.
Style 2 – When the filter indicator changes from green to yellow,
order a new filter. When the indicator changes from yellow to red,
it is recommended that you replace the filter.
Style 3 – When the water filter status display changes from
"GOOD" to "ORDER," order a new filter. When the filter indicator
reads "REPLACE," it is recommended that you replace the filter.
Style 4 – Press FILTER to check the status of your water filter. If
the filter indicator light is yellow, order a new filter. If the filter
indicator light is red, it is recommended that you replace the filter.
Change the water filter cartridge every 6 months. If the water
flow to the water dispenser or ice maker decreases noticeably
before 6 months have passed, replace the water filter cartridge
more often.
*
Class I particle size: >0.5 um to <1 um
**
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
® NSF is a registered trademark of NSF International.
Base Grille Water Filtration System
Model P2WG2L/P2RFWG2 Capacity 200 Gallons (757 Liters)
Model P2WG2/P2RFWG2 Capacity 200 Gallons (757 Liters)
System tested and certified by NSF International against NSF/ANSI
Standard 42 for the reduction of Chlorine Taste and Odor, Particulate
Class I*; and against NSF/ANSI Standard 53 for the reduction of Lead,
Mercury, Benzene, Toxaphene, and O-dichlorobenzene.
Average
Influent Challenge
Influent
Concentration
1.909 mg/L
2.0 mg/L ± 10%
9700000 #/mL
At least 10,000 particles/mL
Average
Influent Challenge
Influent
Concentration
143.33 ug/L
0.15 mg/L ± 10%
140 ug/L
0.15 mg/L ± 10%
0.0058 mg/L
0.006 mg/L ± 10%
0.00646 mg/L
0.006 mg/L ± 10%
0.015 mg/L
0.015 mg/L ± 10%
1.83333 mg/L
1.8 mg/L ± 10%
0.016 mg/L
0.015 mg/L ± 10%
Maximum
Average
Effluent
Effluent
0.05 mg/L
<0.05 mg/L
**
2600 #/mL
62000 #/mL
Maximum
Average
Effluent
Effluent
1.0 ug/L
1.0 ug/L
1.0 ug/L
1.0 ug/L
0.3 ug/L
0.0002 mg/L
1.4 ug/L
0.0004 mg/L
0.5 ug/L
0.0005 mg/L >96.5
4.8 ug/L
0.014 mg/L
1 ug/L
0.001 mg/L
These contaminants are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system.
Refer to the "Warranty" section for the Manufacturer's name,
address and telephone number.
Refer to the "Warranty" section for the Manufacturer's limited
warranty.
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
Minimum %
Average %
Reduction
Reduction
>97.4
>97.4
>97.6
>99.4
Minimum %
Average %
Reduction
Reduction
>99.3
>99.3
>99.3
99.3
>96.5
96.5
76.3
88.1
>96.5
99.7
99.9
>93.2
>93.2
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.85 gpm (3.2 Lpm) @ 60 psi
15

Publicidad

loading