Technical Data
Code
Description
Maximum Pressure
Minimum and Maximum Water Input Pressure
Maximum Flow Rate
Maximum Input Temperature
Power
Noise Level
Vibration Level
Weight
Work Cycle
Conductors
Insulation
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.
WARNING
Power Requirements
WARNING
Tools with double insulation and reinforced insulation are equipped
with a polarized plug (one prong is wider than the other). This plug will only fit in the
right way into a polarized outlet. If the plug cannot be introduced into the outlet, reverse
the plug. If it still doesn't fit, call a qualified electrician to install for you a polarized outlet.
Do not alter the plug in any way. Both insulation types eliminates the need of both a
grounded third power cord with three prongs or a grounded power connection.
WARNING
When using an extension cable, verify the gauge is enough for the
power that your product needs. A lower gauge cable will cause voltage drop in the line, resulting in power loss and
overheating. The following table shows the right size to use depending on cable's length and the ampere capability shown in
the tool's nameplate. When in doubt use the next higher gauge.
Ampere
Capacity
from 0 A and up to 10 A
from 10 A and up to 13 A
from 13 A and up to 15 A
from 15 A and up to 20 A
WARNING
When operating power tools outdoors, use a
extension cable labeled "For Outdoors Use". These extensions are especially designed
for operating outdoors and reduce the risk of electric shock.
127 V
50 minutes' work per 20 minutes' rest Maximum 3 hours daily.
16 AWG x 2C with 140 °F insulation temperature
Class II
Power Cord Grips used in this product: Type "Y".
Number of
Conductors
3 (one grounded)
* It is safe to use only if the extensions have a built-in artifact for over current protection.
AWG = American Wire Gauge. Reference: NMX-J-195-ANCE
HILA-1500P
26023
Electric Pressure Washer
1 500 PSI
14 PSI - 58 PSI
1,2 gpm
122 ºF
Frequency
92 dB
1,8 m/s2
9,9 lb
IP Grade
Tool Build Quality: Reinforced
Thermal insulation on motor winding: Class F
Authorized Service Center.
Extension gauge
from 6' to 49'
18 AWG( * )
16 AWG
14 AWG
8 AWG
grounded
60 Hz
IPX5
|
higher than 49'
16 AWG
14 AWG
12 AWG
6 AWG
ENGLISH
3