Part no
2050505683
Issue no
1
Series no
C
Date
2006-12
Page
48/49
Test equipment/procedure
Static measurement / Dynamic measurement
Workshop
R
Joint Simulator for Static Transducer
Part Number
Model
615 910 927 0
ACS5.01
615 910 928 0
ACS6.05
615 910 929 0
ACS6.10
615 910 930 0
ACS8.05
615 910 931 0
ACS8.10
615 910 932 0
ACS10.10
615 910 933 0
ACS10.50
615 910 934 0
ACS10.50
615 910 935 0
ACS10.50
Stationary Transducer
Part Number
Model
615 165 141 0
ST4001
615 165 142 0
ST4005
615 165 143 0
ST4010
615 165 144 0
ST4050
In Static as well as Dynamic measurement, it is advised to double check by the use of a
Dial Indicating Torque Wrench* (direct reading) or a Torsion Static Torque Wrench**
(connected to the Delta 4000 or Sigma 2001).
For further information regarding our complete measurement range, see our general
catalogue.
Test joint
Transducer
Thread
ST4001
M5
ST4005
M6
ST4010
M6
ST4005
M8
ST4010
M8
ST4010
M10
ST4050
M10
ST4050
M12
ST4050
M16
Torque
Torque
Range Nm
Range ft.lb
1-15
0,7-11,1
5-70
3,7-51,6
10-150
7,4-110,5
50-700
36,8-516
Assembly line
R
Your actual joint

Publicidad