Descargar Imprimir esta página

Cameo F4 FC PO IP65 Manual De Usuario página 14

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 50
USING THE OPERATING POLE FOR SETUP, INSTALLATION, AND CONFIGURATION
Thanks to its four plastic feet, the spotlight can be placed in a suitable location on a flat surface. Install on a crossbeam using the integrated
28 mm TV spigot (A) and a suitable crossbeam clamp (not supplied). Make sure that the spotlight is firmly attached and secure it using a
suitable safety cable on the designated location on the top of the spotlight (B). Use the laterally attached yellow bell-shaped knob (C) to
adjust the beam angle (zoom) with the operating pole. The blue bell-shaped knob (D) is used to horizontally adjust the beam direction (pan)
and the white bell-shaped knob (E) to vertically adjust beam direction (tilt). A 6 mm hex key (F) is used to adjust the tilt for the slip clutch in
the drive unit.
Important safety information Overhead installation requires extensive experience, which includes calculating the limit
values of the working load of the installation material to be used and regular safety inspections of all installation material and
spotlights. If you do not have these qualifications, do not attempt to carry out the installation yourself; contact a professional
company.
C
BARN DOOR AND FILTER FRAME INSTALLATION / DISASSEMBLY / CLEANING OF LENSES
Separate the device completely from the power supply. To install or disassemble the barn door and filter frame, please press the
spring-loaded lock pins (A) on the retaining bracket so that it flips upwards. Return the retaining bracket to the original position so that the
lock pins click back into their locked position.
The Fresnel lens (B) and its rubber frame as well as the glass lens behind it (C) can be cleaned by flipping the retaining bracket upwards
as previously described and then drawing the Fresnel lens and its rubber frame upwards out of theretaining bracket. Clean the Fresnel lens
with a moist, lint-free cloth. The glass lens should be cleaned with a special optical cloth. Put the Fresnel lens in front of the glass lens and
return the bracket mechanism to its downward position until the lock pins click into place.
A
Important safety notice!
For safety reasons, the filter frame must always be in the respective bracket on the spotlight, even if no filter is inserted!
14
A
F
E
D
B
B
C

Publicidad

loading

Este manual también es adecuado para:

Clf4fcpoip