USING
THE CLEANER
CONTROL PANEL
A - On/off switch
B - Detergent control tap (if
available).
STARTING THE CLEANER
1) Turn on the water supply tap (fig. 5A).
2) Connect the water cleaner to the mains electricity supply by
plugging the plug into the socket.
3) Start the cleaner by turning the selector switch to pos. I
(fig. 7A).
!
Warning
The high pressure water jet generates a reaction force in the
lance. Keep a firm grip on the lance handle.
4) Press the trigger on the gun and begin washing.
5)
To operate the water cleaner with hot water, turn the ON/OFF
switch to the Hot Water position. (fig. 7A).
!
Warning
In water cleaners with the "Total Stop" system, the motor starts
and stops when the lever on the lance handle is actioned or
released.
!
Danger
Do not block the handle lever in the delivery position.
IMPORTANT!
To eliminate any impurities or air bubbles from the water
circuit we advise starting the cleaner for the first time
without the lance and letting the water run out for a few
seconds.
Impurities could block the nozzle and cause malfunction
(Fig. 8).
USING THE ACCESSORIES.
USING THE MULTIREG
ADJUSTABLE NOZZLE (fig.
9)
Pressure must be selected
with the gun switched off.
Low pressure washing and
detergent suction.
(Version with detergent
suction).
Shift the nozzle forward.
English
Washing at high pressure
with a concentrated jet of
water
Turn the nozzle in an anti-
clockwise direction.
Washing at high pressure
with a fan-shaped jet of
water
Turn the nozzle in a clockwise
direction.
ROTARY HEAD (optional
accessory)
FIG. 7
The high pressure washer
can be fitted with a head with rotary nozzle to clean the most
stubborn dirt.
!
Danger:
Aim the jet from a certain distance to avoid damage caused by
the high pressure.
Do not aim the jet at people, animals or electrical sockets.
STOPPING THE CLEANER
1)
Turn the burner off by rotating the ON/OFF switch to the "I"
position (fig. 7A).
2) Let the cleaner run with cold water only for at least 30 seconds
to cool down the boiler.
3) Stop the cleaner by turning the selector switch to pos. "0"
(fig. 7A).
4) Discharge the pressure from the H.P. hose by pressing the
trigger on the gun.
5)
Disconnect the water cleaner from the mains electricity
supply via the Solenoid switch or by unplugging the plug from
the socket.
6) Turn off the water supply tap (fig. 5A).
!
Warning
- If the water cleaner is left, even temporarily, turn it off by using
the Solenoid switch or by unplugging the plug from the socket.
- Water cleaners with the "Total Stop" device should be con-
sidered as off when the Solenoid switch is in the "O" position
or the plug is unplugged from
the socket.
- When the water cleaner is not
used, close the safety device
on the handle.(fig.10).
- Dry use of the water cleaner
causes serious damage to
pump gaskets.
FIG. 8
- 22 -
FIG. 9
FIG.10