Descargar Imprimir esta página

Gaggenau CM 450 712 Manual De Instalación página 14

Publicidad

Idiomas disponibles

Idiomas disponibles

Prepare built-in units
Important:
The power outlet must be located outside the
built-in cut-out.
Make sure there is adequate aeration. To do this,
remove the rear panel or cut out an opening of 19
15
" (500 x 400 mm). There must be a gap of at least
3
4
1
3
" (35 mm) between the wall and base of the unit or
8
the rear panel of the unit situated above. The ventilation
slots and intake openings must not be covered. Also
follow the installation instructions for the appliance
situated above or below. If installing the appliance
above a warming drawer, the height of the recess must
be 23
1
" (590 mm). If the appliance is installed directly
4
under a décor panel, ensure that there is a ventilation
slot of at least 31 square inches (200 cm
appliance should not be installed too high, approx. 37
(950 mm), to ensure that function parts, e.g. container
or brewing unit, can be removed without difficulty. The
display should not be located above eye level to ensure
legibility.
Protect the appliance against freezing or it will be
damaged.
9
CAUTION
Installation must always be performed by two
persons.
14
Installation preparation
1
2
" x
11
16
2
). The
"
3
8
3
4
5
6
7
8
Unpack all the parts and check for any damage in
transit. Do not operate a damaged appliance.
Take note of the installation dimensions of the
particular model.
Fig. 2
Two opening angles can be selected for
Important:
the door. Depending on the opening angle
required, the mounting distance to the wall should
be observed before installation.
‒ Opening angle approx. 110° (delivery status)
= mounting distance to the wall at least 13
(350 mm).
‒ Opening angle approx. 155°
= mounting distance to the wall at least 25
(650 mm).
For an opening angle of 155°, remove both the
restrictors at the top and bottom of the hinge.
Position the assembly bracket
measurement stated in the image and fasten it with
2 fastening screws
to the cabinet as shown. The
(f)
assembly bracket must be positioned at the base of
the unit and the wall such that no gap is present.
Fig. 3
Fasten the transformer mount
in the middle.
Fig. 4
Insert the transformer in the mount. The
connections to both lines must point to the left.
Fig. 5
Note: When positioning the transformer
pushing in the appliance, do not trap the lines.
The transformer
is not allowed to touch the
(k)
appliance and the back wall of the cupboard.
Set the main switch
(U)
Fig. 6
Note: The appliance can be directly connected to
the home network. To do this, insert a LAN cable
(not included in scope of supply) into the appliance.
Important: Fig. 7
‒ The distance between the appliance and the rear
wall must be at least 13
‒ The power cord or the LAN cable must not be
kinked or crushed.
‒ A recess of 4
23
" (120 mm) x 11
32
required for water inlet hose and drain water
hose. If required, adjust the furniture base
accordingly.
‒ The hose guide
should end at the edge of the
(l)
furniture base.
‒ The connecting hose guide
adapted to the edge of the furniture if necessary.
Screw the hose guide
(l)
(i)
to the rear wall of the appliance.
Insert the drain water hose in the hose guide
Fig. 1
"
3
4
9
/
16
(c)
according to the
with 2 screws
(d)
and
(k)
Û
to [
] on the appliance.
" (100 mm).
15
16
13
" (300 mm) is
16
(l)
should be
with the fastening screw
Fig. 8
.
(l)
"
(f)

Publicidad

loading

Este manual también es adecuado para:

Cm470712Cmp 250 711