Troubleshooting
Fault
Potential Failure
The appliance is
The unit is not switched on
not working
Plug and/ or lead are damaged
Fuse in the plug has blown
Power supply
The appliance
Condenser blocked with dust
turns on, but the
temperature
Doors are not shut properly
is too high/ low
Appliance is located near a heat
source or air flow to the condenser is
being interrupted
Ambient temperature is too high
Unsuitable foodstuffs are being
stored in the appliance
Appliance is overloaded
The appliance is
Loose nut/ screw
unusually loud
The appliance has not been installed
in a level or stable position
P2M005STD-Ver1.2
Problem solving action
Check the unit is plugged in correctly and
switched on
Call your agent or qualified technician
Replace the fuse (UK Plug)
Check power supply
Call your agent or qualified technician
Check doors are shut and seals are not
damaged
Move the refrigerator to a more suitable
location
Increase ventilation or move appliance to a
cooler position
Remove any excessive hot foodstuffs or
blockages to the fan
Reduce the amount of food stored in the
appliance
Check and tighten all nuts and screws
Check installation position and change if
necessary
12