Descargar Imprimir esta página

Chauvet Professional REM 1 Guía De Referencia Rápida página 2

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

EN
Safety Notes
These Safety Notes include important information about installation, use, and maintenance of the REM 1 and REM 1SQ.
CAUTION:
This product's housing may be hot when operating. Mount this product in a location with adequate
ventilation, at least 20 in (50 cm) from adjacent surfaces.
When transferring the product from extreme temperature environments, (e.g., cold truck to warm humid
ballroom) condensation may form on the internal electronics of the product. To avoid causing a failure,
allow the product to fully acclimate to the surrounding environment before connecting it to power.
ALWAYS:
Use a safety cable when mounting this product overhead.
Connect this product to a grounded and protected circuit.
DO NOT:
Open this product. It contains no user-serviceable parts.
Leave any flammable material within 50 cm of this product while operating or connected to power.
Connect this product to a dimmer or rheostat.
Operate this product if the housing, lenses, or cables appear damaged.
Operate this product outdoors or in any location where dust, excessive heat, water, or humidity may affect
it (IP30).
Operate this product at an altitude exceeding 5000m.
ONLY use the hanging/mounting bracket to carry this product.
The minimum startup temperature is -4°F (-20°C). Do not start the product at lower temperatures.
The maximum ambient temperature is 95°F (35 °C). Do not operate this product at higher temperatures.
To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the
product from power via breaker or by unplugging it.
In the event of a serious operating problem, stop using immediately.
FCC Statement of Compliance
This device complies with Part 15 Part B of the FCC rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's
authority to operate the equipment.
The use of certain substances in electrical and electronic equipment is restricted with the EU. For
further information, see directive 2011/65/EU.
What is Included
REM1
1 case (4 REM1)
1 Seetronic® PowerKON® power cable
4 Seetronic® PowerKON® power linking cables
REM1SQ
1 case (8 REM1SQ)
1 Seetronic® PowerKON® power cable
8 Seetronic® PowerKON® power linking cables
AC Power
This product has an auto-ranging power supply that can work with an input voltage range of 100–240 VAC, 50/60 Hz.
1
QUICK REFERENCE GUIDE
4 Seetronic® etherKON® signal linking cables
5 spare LED masks
User manual
8 Seetronic® etherKON® signal linking cables
5 spare LED masks
User manual
REM 1 and REM 1SQ QRG Rev. 2

Publicidad

loading

Este manual también es adecuado para:

Rem 1sq