Flash Patterns
To select a flash pattern, apply power to the RED or WHITE or both RED and WHITE wires. (WHITE wire is for dual color only). Momentarily
touch the BLUE wire to the BLACK wire (ground) for less than 1 second to advance to the next pattern. To go back to the previous pattern,
momentarily touch the BLUE wire to the BLACK wire for approximately 2 - 3 seconds. To force the flash pattern to STEADY, momentarily
touch the BLUE wire to the BLACK wire for approximately 5 seconds. When Vacuum-Magnet Mount is being used, the BLUE wire is con-
nected to ground via the momentary switch on the cigarette plug as shown in FIGURE 2. For more detail about flash patterns, please see the
SINGLE and DUAL COLOR FLASH PATTERN TABLES below.
Synchronization:
The permanent mount microbars sync with compatible ECCO products via the yellow wire:
Determine the desired style of flash pattern for each unit and set each unit individually (without the yellow wires connected together) to avoid
confusion. It is also strongly recommended that the same style of flash pattern be used on all units to produce the most effective warning pat-
tern. (NOTE: Phases A and B for each style of flash pattern in the table denote the relative timing between units connected in a synchronizing
installation. To operate simultaneously, each unit must be set to the same phase (A + A or B + B); to operate alternately, units must be set to
have the opposite phase (A + B or B + A)).
Connect the yellow sync wires together and check that the units are flashing in a synchronized manner as expected. If a pattern on one unit
appears incorrect, the blue pattern select wire can be used to cycle forward or backward on that individual unit until the correct pattern is
selected. Note: This will only change the pattern in the one unit and will not affect the other units connected to the yellow sync wire.
If the yellow wire is unused, leave unconnected and insulated.
Dimming Feature:
To activate the dimming feature of this microbar, attach the BLUE wire to the RED wire (+BATT).
New Beacon & Minibar Single Color
PATTERN MODE
1
Single Flash Phase 1 (DEFAULT)
1
2
Single Flash Phase 2
3
Single Flash Alternating Split
4
Single Flash Phase 1
2
5
Single Flash Phase 2
6
Single Flash Alternating Split
7
Double Flash Phase 1
3
8
Double Flash Phase 2
9
Double Flash Alternating Split
10
Double Flash Phase 1
4
11
Double Flash Phase 2
12
Double Flash Alternating Split
13
Quad Flash Phase 1
5
14
Quad Flash Phase 2
15
Quad Flash Alternating Split
16
Quad Flash Phase 1
6
17
Quad Flash Phase 2
18
Quad Flash Alternating Split
19
Triple Flash Phase 1
7
20
Triple Flash Phase 2
21
Triple Flash Alternating Split
22
Quint Flash Phase 1
8
23
Quint Flash Phase 2
24
Quint Flash Althernating Split
25
Double Diagonal Phase 1
9
26
Double Diagonal Phase 2
27
Double Diagonal Alternating Split
28
Quad Diagonal Phase 1
10
29
Quad Diagonal Phase 2
30
Quad Diagonal Alternating Split
11
31
Fast Rotate
12
32
Rotate/Quad
13
33
Wave Rotate
14
34
Random
15
35
ActionScan (DEFAULT for just 17" mini bar)
16
36
ZigZag
17
37
Steady Burn
DESCRIPTION
SAE J845
5517
Amber
SYNC
FPM
Yes
Class 1A
75
Yes
Yes
Yes
Class 1A
Yes
120
Yes
Yes
Class 1A
75
Yes
Yes
Yes
Class 1A
Yes
120
Yes
Yes
Class 1A
75
Yes
Yes
Yes
Class 1A
Yes
150
Yes
Yes
Class 1A
75
Yes
Yes
Yes
Class 1A
Yes
150
Yes
Yes
Yes
150
Yes
Yes
Yes
150
Yes
Yes
120
Yes
150/75
Yes
70
No
No
Yes
70
Added March 2022 for 17" minibar. Std going fwd
No
CA Title 13
ECE R65
5517
5517
Amber
Amber
Class B
Class 1
Class B
Class 1
Class B
Class 1
Page 4 of 7