DMX-512 CONNECTION
If you are using a standard DMX controller, you can connect the DMX-output of the controller directly to the DMX-input of the
first unit in a DMX-chain. Always connect the output of one unit with the input of the next unit until all units are connected.
If you use a controller with 5 pin DMX connection you will need to use a 5-pin to 3-pin adapter.
At the last fixture, the DMX cable has to be terminated. Solder a 120 Ohm resistor between signal (-) and signal (+)
into a 3-pin XLR connector and plug this into the DMX output of the last fixture in the chain.
REMOTE
Button
Function
Power
Power On/Off
Auto
Activate the automatic mode.
Sound 1
Activate the sound program 1.
Sound 2
Activate the sound program 2.
Sound 3
Activate the sound program 3.
Strobe
Activate the strobe mode.
<- Auto +>
Set the auto program using '+' and '-' buttons.
<- Speed +>
Set the run speed/sensitivity using '+' and '-' buttons.
<- Strobe +>
Set the strobe mode run using'+' and '-' buttons.
CAUTION! The remote control is supplied with a battery inserted. An insulating foil between the
battery and the battery contacts prevents the battery from being discharged during storage.
Prior to the first operation remove the foil from the battery support on the rear side of the remote
control. Otherwise operation of the remote control is not possible.
REPLACING THE FUSE
If the fuse is defective, replace the fuse with a fuse of the same type and value. Before replacing the fuse, unplug mains lead.
Procedure:
Step 1: Open the fuse holder on the rear panel with a fitting screwdriver.
Step 2: Remove the old fuse from the fuse holder.
Step 3: Install the new fuse in the fuse holder.
Step 4: Replace the fuse holder in the housing.
FIXTURE CLEANING
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output.
Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding
can cause greater accumulation of dirt on the unit's optics.
Make sure the area below the installation place is free from unwanted persons during servicing
Housings, fixations and installations spots( ceiling, truss, suspensions) should be totally free from any deformation
The mains cables must be in impeccable condition and should be replaced immediately when even a small problem is
detected
In order to protect the fixture from overheat the cooling fans (if any) and ventilation openings should be cleaned
monthly.
The interior of the fixture should be cleaned annually using a vacuum cleaner or air-jet.
Clean with soft cloth using normal glass cleaning fluid.
Always dry the parts carefully.
Clean the external optics at least every month. Clean the internal optics at least every 30/60 days.
ATTENTION: We strongly recommend internal cleaning to be carried out by qualified worker!